DC/DC Converter
WRE_S - 3WR2 & WRF_S - 3WR2 Series
Parameter description:
Model
FUSE
MOV
LDM1
C0
Vin:5VDC
Vin:12VDC
Vin:24VDC
Vin:48VDC
Slow blown fuses according to the actual input current selections of the clients
--
S14K20
12μH
S20K30
μH
S14K60
12μH
12μH
12
330µF/50V
680µF/25V
330µF/100V
4.7µF/100V
4.7µF/100V
C1
4.7µF/50V
4.7µF/50V
C2
C3
Refer to the Cout in Fig.2
CY1
D1
1nF/3KV
RB160M-60/1A
VC -VD -1.0
R =
-300
R
IC
In accordance with the formula:
47nF/100V
Cd
Notes:
① Part ① in Fig. 3 is used for EMS test while part ② is used for EMI filtering; and parts ① and ② may be selected based on needs.
② VC is the voltage of the Ctrl end relative to the GND of the input grounding; VD is the positive-going conduction pressure drop of D1; IC is the current flows
into the Ctrl end and its value is generally 5-10mA, see Fig. 3-③ for the peripheral circuit of Ctrl end;
③ If there is no recommended parameters, no external component is required.
3. Ctrl end
The modules are of normal output when the Ctrl end is suspended or of high resistance; the modules turn off when connecting with high
level (relative to the input grounding); notice that the current flows into the pin shall be 5 - 10mA, the modules will be permanently damaged
if the current exceeds its max. value (20mA in general).
The value of R can be derived as follows:
VC -VD -1.0
R =
-300
IC
For Detailed parameter, please refer to EMC solution-recommended circuit in this manual.
4. Input current
When the electricity is provided by the unstable power supply, please make sure that the range of the output voltage fluctuation and the
ripple voltage of the power supply do not exceed the indicators of the modules. Input current of power supply should afford the flash startup
current of this kind of DC/DC module(see Fig. 5).
Generally: Vin= 5V series Iave =1315mA
Vin=12V series lave =631mA
Vin=24V series lave =303mA
Vin=48V series lave =158mA
Iave
Input Voltage
scope
Input Voltage (V)
Fig. 5
5. Output load requirements
When using, the minimum load of the module output should not be less than 5% of the nominal load.In order to meet the performance
parameters of this datasheet, please connect a 5% dummy load in parallel at the output end, the dummy load is generally a resistor, please
note that the resistor needs to be used in derating.
6. For more information please find DC-DC converter application notes on www.mornsun-power.com
2016.01.25-B/0
Page 5 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation