Table 2. Electrical Performance, CMOS Option
Parameter
Output Frequency1, Ordering Option
Supply Voltage3, Ordering Option
Supply Current
Symbol
Min.
5
Typ
Max
52
Units
MHz
V
fO
VDD
IDD
+2.8, +3.0, +3.3, +5.0
6.0
mA
Operating Temperature, Ordering Option
TOP
0/55, -10/70, -20/70, -30/80, -30/85, -40/85
°C
Frequency Stability
Stability Over TOP4 , Ordering Option
Frequency Tolerance5
FSTAB
FTOL
±0.05, ±0.10, ±0.20, ±0.28, ±0.50
ppm
ppm
ppm
ppm
ppm
±2.0
±0.2
±0.2
±1.0
Power Supply Stability, ±5%
Load Stability, ±10%
FPWR
FLOAD
FAGE
Aging / 1st year
Frequency Tuning (EFC), Ordering Option
Tuning Range6
PR
±5.0, ±8.0, ±10.0, ±12.0
ppm
Tuning Slope
Positive
1.5
Control Voltage to reach Pull Range
Control Voltage Impedance
VC
0.5
2.5
V
100
Kohm
RF Output (CMOS), Ordering Option
Output Level High
Output Level Low
VOH
VOL
0.9*VDD
V
0.1*VDD
Output Load
Duty Cycle
CL
15
55
2
pF
%
45
Start Up Time
Rise & Fall Times
tSU
ms
ns
tR/tF
4
Output Enable7
Output Disable
VIH
VIL
0.7*VDD
V
V
0.3*VDD
Phase Noise8
Phase Noise, 10.00MHz8
10Hz
100Hz
1kHz
10kHz
100kHz
0N
dBc/Hz
-101
-124
-144
-154
-156
1. Refer to Table 8 for Standard Frequencies. Other Frequencies are available on request. Check with factory.
2. Output DC-cut capacitor is optional.
3. The VT-702 power supply pin (Pin9) should be filtered using a by-pass capacitor of 0.1uF for optimal performance.
4. Referenced to the midpoint between minimum and maximum frequency value over Operating Temperature Range.
5. Frequency measured at 25 °C, 1 hour after 2 IR reflows.
6. Referenced to Mid Control Voltage.
7. Output is enabled, if Pin8 is left open.
8. Measured at ambient temperature using Agilent E5052B Signal Source Analyzer
Vectron International • 267 Lowell Road, Suite 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Page3