AC-DC Power Supplies
VER18 Series
18 Watt
• Energy Efficiency Level VI
xxx Series
• European CoC Tier 2
• Interchangeable Mains Connectors Included
• Universal Input
• Output Voltages from 9 V to 24 V
• Class II Construction
B R A N D
• Low Cost
Dimensions:
The VER18 series of wall plug adaptors comply with the very latest energy efficiency VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive applications while
maintaining industry leading performance.
VER (body only):
3.54 x 1.69 x 1.68” (90.5 x 42.0 x 42.7 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation(2)
Output Connector
Model Number
9.0 V
2000 mA
1500 mA
5%
5%
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
VER18US090-JA
VER18US120-JA
12.0 V
15.0 V
18.0 V
24.0 V
1250 mA
1000 mA
750 mA
5%
5%
5%
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
VER18US150-JA
VER18US180-JA
VER18US240-JA
18 W
Notes
1. Other output voltages available, contact sales for details.
2. Total regulation includes initial set accuracy, line and load regulation.
Input
Characteristic
Minimum
Typical
Maximum
264
Units
VAC
Hz
Notes & Conditions
Input Voltage
90
47
Input Frequency
Input Current
63
0.23
60
A
100 VAC
Inrush Current
Power Factor
A
240 VAC, cold start at 25 °C
EN61000-3-2, class A
No Load Input Power
Input Protection
75
mW
Internal T1.0A/250 VAC fuse
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Minimum
Typical
Maximum
Units
V
Notes & Conditions
9
0
24
See Models and Ratings table
No minimum load required
A
4
s
30
ms
ms
%
10
Full load and 100 VAC
Total Regulation
5
4
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Transient Response
Ripple & Noise
% deviation
mV pk-pk
Measured with 20 MHz bandwidth and 47 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
150
Short Circuit Protection
Temperature Coefficient
Continuous, trip and restart (hiccup mode) with auto recovery
0.05
%/˚C
www.xppower.com