UHP-28.2/12-D48
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters
ORDERING GUIDE SUMMARY
Model
VOUT Range
28.2V
IOUT Range
VIN Range
Ripple/Noise
Efficiency
UHP-28.2/12-D48
0-12A
36-75V
100mVp-p
91.5%
INPUT CHARACTERISTICS
Parameter
Typ. @ 25°C, full load
36-75 Volts
5.77 Amps
32 Volts
Notes
Voltage Range
48V nominal
VIN = 48V
Current, full power
Undervoltage Shutdown
Short Circuit Current
Remote On/Off Control
200mA
VIN = 48V
Typical unit
0 to +VIN
Positive or negative logic
FEATURES
OUTPUT CHARACTERISTICS
Parameter
Typ. @ 25°C, full load
28.2 Volts 10%
0 to 12 Amps
342 Watts max.
1.25%
Notes
N
N
N
N
N
N
N
N
N
N
N
Wide 36-75V input range
Voltage
Trim range shown
No minimum load
28.2V output @ 12 Amps. max.
Current
Very high efficiency of 91.5%
Power Output
Max. baseplate @ 342W = 80°C
Operates to +110°C baseplate w/derating
Conduction-cooled baseplate, no fans
Industry-standard mounting and pinout
Remote sense, trim and On/Off control
Isolated to 2250Vdc (Basic insulation)
Multiple I/O protection features
Accuracy
Ripple & Noise
100mVp-p
20MHz bandwidth
Line and Load Regulation
Overcurrent Protection
Overtemperature Protection
Efficiency (minimum)
Efficiency (typical)
0.05%/ 0.1%
30 Amps
With hiccup auto-restart
+125°C
89.5%
91.5%
UL/EN60950-1 safety approvals, CE mark
ETSI 300-019-2-4 surge, shock/vibration
GENERAL SPECIFICATIONS
Parameter
Typ. @ 25°C, full load
100μsec
Notes
Dynamic Load Response
Operating Temperature Range
Operating Temperature Range
Safety
50-75-50% step to 1 of final value
With baseplate, see derating curve
Without baseplate
DESCRIPTION
–40 to +110°C
–40 to +32°C
The UHP-28.2/12-D48 is especially designed for
unattended cellular and PCS base stations, remote
wide band RF amplifiers and wireless communi-
cation facilities. To avoid unreliable system fans,
the UHP-28.2/12-D48 can be operated using con-
duction cooling while attached to a housing wall
or system heat sink. No forced airflow is needed
up to +110°C baseplate temperature.
UL/IEC/EN 60950-1
And CSA C22.2-No.234
MECHANICAL CHARACTERISTICS
With baseplate
2.30 x 2.40 x 0.502 inches (58.4 x 61.0 x 12.8 mm)
2.30 x 2.40 x 0.452 inches (58.4 x 61.0 x 11.5 mm)
Without baseplate
The UHP-28.2/12-D48's MTBF is 3 million hours
(+40°C GF) and ruggedization conforms to
ETSI 300-019-2-4. Multiple protection features
avoid damage to outside equipment and to the
converter itself. The converter will shut down on
sustained input undervoltage, output overcurrent,
output short circuit and overvoltage and thermal
shutdown. Overload currents less than a short
circuit limit the output current so that operation
is not interrupted. Upon short circuit shutdown,
the converter will automatically attempt to restart
(“hiccup” mode) when the overload is removed.
The input will tolerate up to 100V overvoltage
spikes (100msec).
The UHP-28.2/12-D48 uses industry-standard
half-brick external outline dimensions, pinout and
mechanical mounting. The overall unit is designed
to be as “lead-free” as practical in construction
and method of attachment (no lead added in
assembly).
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
UHP_28.2/12_D48.B02 Page 1 of 9