TT100-SD

更新时间: 2022-02-26 13:25:48
品牌 Logo 应用领域
莱姆 - LEM /
页数 文件大小 规格书
4页 1275K
描述
AC Current transformer

TT100-SD 数据手册

 浏览型号TT100-SD的Datasheet PDF文件第2页浏览型号TT100-SD的Datasheet PDF文件第3页浏览型号TT100-SD的Datasheet PDF文件第4页 
AC Current transformer TT 100-SD  
IPN = 100 A  
Split core transducer for the electronic measurement of AC waveform  
currents,withgalvanicisolationbetweentheprimarycircuit(power)and  
the secondary circuit (measurement).  
Electrical data  
IPN  
IOUT  
VSZ  
ÎP  
Primary nominal current rms  
Output current  
Output clamping voltage  
Overload capability - continuous  
- 1 min  
100  
33.33  
7.5  
300  
4000  
At  
mA  
V
A
A
Features  
· Split core type  
· Ø 16 mm sensing aperture for non-  
contact measurement  
· Cable output (1m)  
· Isolated plastic case recognized  
according to UL 94-V0.  
Performance data  
X
Overall accuracy @ IPN , TA = 25°C  
Linearity error  
< ± 1  
0.1  
60  
1.5° ± 1°  
50/60  
%
%
ppm/K  
eG  
L
TCIOUT  
Dj  
Temperature coefficient of IOUT  
Phase shift  
Advantages  
· High accuracy and low phase shift  
· High isolation between primary and  
secondary circuits  
BW  
Frequency bandwidth (± 1dB)  
Hz  
General data  
· Compact case  
· Cost-effective solution  
· Easy installation.  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
Mass  
- 25 .. + 70 °C  
- 30 .. + 90 °C  
100  
g
IPxx  
Protection degree  
IP40  
Applications  
· Power meters  
Isolation characteristics  
Current measurement for active  
power calculation  
Vb  
Rated isolation voltage rms1)  
with IEC 61010-1 standards and following conditions :  
- Reinforced isolation  
300  
V
· Energy sub-meters  
For energy efficiency monitoring,  
consumption analysis and costs  
allocation  
- Over voltage category CAT III  
- Pollution degree PD2  
- Heterogeneous field  
Rms voltage for AC isolation test 2), 50Hz, 1min  
Impulse withstand voltage 1.2/50ms  
Creepage distance  
Clearance distance  
Comparative tracking index (Group I)  
3.5  
6.5  
6
6
600  
kV  
kV  
m m  
m m  
· Power quality monitoring  
· Condition monitoring  
(e.g. motor loads such as  
conveyers, pumps or HVAC)  
· Distributed measurement systems  
Vd  
Vw  
dCp  
dCl  
CTI  
1)  
2)  
Application domain  
Notes :  
If insulated cable is used for the primary circuit, the voltage category  
could be improved according to the primary cable insulation category  
(please refer to the cable manufacturer's indications)  
· Energy and Automation  
between primary (completely filling the hole) and secondary.  
Page 1/4  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
071115/5  
www.lem.com  

与TT100-SD相关器件

型号 品牌 描述 获取价格 数据表
TT101 SWITCH Interconnection Device,

获取价格

TT101F ETC SCR / Diode Modules

获取价格

TT101F08KFB INFINEON Silicon Controlled Rectifier, 200A I(T)RMS, 101000mA I(T), 800V V(DRM), 800V V(RRM), 2 Ele

获取价格

TT101F08KFB-A INFINEON Silicon Controlled Rectifier, 101000mA I(T), 800V V(RRM), 2 Element

获取价格

TT101F10KSB-K INFINEON Silicon Controlled Rectifier, 200A I(T)RMS, 101000mA I(T), 1000V V(DRM), 1000V V(RRM), 2 E

获取价格

TT101F10KSC INFINEON Silicon Controlled Rectifier, 101000mA I(T), 1000V V(RRM)

获取价格