TRG70A Series
7 0 W AT T S - A C / D C G E N E R A L S I N G L E O U T P U T
FEATURES
•
•
•
•
•
•
•
•
Wide input voltage
Continuous short circuit protection
Over voltage protection
Output voltage available from 12VDC to 48VDC
High efficiency 87% typical
Meets EN55022 Class ”B”, conducted emissions
MEPS compliance, Efficiency Mark V
ROHS compliance
SPECIFICATIONS
INPUT
STANDARDS AND APPROVALS
Safety standards
Queensland Electrical Safety Office
Certificate of approval Qld Q080453,
AS/NZS 609050.1:2003, EN60950
Voltage range
Frequency
90 to 264Vac
50Hz to 60Hz
Inrush current
Isolation
60A max @ 240Vac
Input to Output 4,242Vac
3.5mA max.
C-tick
AS/NZS CISPR 11:2002 Group 1
EMI standards
RCM
Meets EN55022 Class B and CISPR/FCC Class B
Complies with AS/NZS 4417 Parts 1,2,3 N911
Leakage current
OUTPUT
MECHANICAL
Dimensions
Weight
Output voltage
Voltage set-point
Ripple and noise
Short circuit protection
Over voltage protection
Factory preset, see table (not adjustable)
+/-2% (60% load)
132 x 58 x 30.5mm
345g
1% p-p max
AC Inlet
IEC320/C14
Continuous (Auto recovery)
Yes
Output connector
Right angle, hollow barrel connector, 2.5mm
inside diameter; 5.5mm outside diameter;
9.5mm length Center positive polarity.
Hold-up time
8ms typ @ 115Vac
DC cord length
720mm with ferrite core 18AWG/UL1185
Load regulation
+/-2 to +/-5% (20% to 100% load)
Model dependent
Line regulation
ENVIRONMENTAL
+/-1% max 100Vac to 240Vac at full load
SELECTION TABLE
Consult Powerbox for variation of output connector and DC cord length
Operating temperature
Load derating
0°C to +60°C
RATED
VNOM
OUTPUT
MAX
MODEL NUMBER
CURRENT
POWER
Derate from 100% at 40°C linearly to 50% at
60°C
TRG70A120- 21E11-V
TRG70A150- 21E11-V
TRG70A180- 21E11-V
TRG70A190- 21E11-V
TRG70A240- 21E11-V
TRG70A480- 21E11-V
12Vdc
15Vdc
18Vdc
19Vdc
24Vdc
48Vdc
5.5A
4.6A
3.9A
3.7A
3.0A
1.5A
66W
69W
70W
70W
72W
72W
Storage temperature
-20°C to +85°C
TECHNICAL ILLUSTRATION
Doc. No. PBC9 Rev.C 28-4-11
286