TPT1043
Low-Power Fault Protected High-Speed CAN FD Transceiver with
Sleep Mode
Electrical Characteristics
All test conditions: VCC = 4.5 V to 5.5 V, VIO = 2.8 V to 5.5 V, VBAT = 4.5 V to 40 V, RL = 60 Ω, T = −40°C to 125°C, unless
otherwise noted.
Parameter
Pin VCC (Power Supply)
Test Conditions
Min
Typ
Max
Unit
VCC
Supply Voltage
ꢀ
4.5
-
-
5.5
4.4
V
V
Undervoltage Recovery on VCC for
Protected Mode
UVVCC_R
VCC Rising
3.6
Undervoltage Detection on VCC for
UVVCC_F
VCC Falling
3
-
3.4
200
45
-
-
V
Protected Mode
(1)
VHYS_UVVCC Hysteresis Voltage on UVVCC
ꢀ
mV
mA
Normal mode (dominant), VTXD
= 0 V, RL = 50 Ω, CL = open
-
65
Normal mode (recessive), VTXD
= VIO, RL = 50 Ω, CL = open
-
-
1.2
2
3
3
mA
µA
Standby/Sleep mode VBAT
VCC, RL = 50 Ω, CL = open
>
ICC
Supply Current
Dominant with bus fault, short
circuit on bus line, VTXD = 0 V,
−3V < (VCANH = VCANL) < +18V,
RL = Open, CL = open
-
63
110
mA
Pin VIO (I/O Supply)
VIO
Supply Voltage on VIO Pin
ꢀ
2.8
-
-
5.5
2.5
V
V
Undervoltage Recovery on VIO for
Protected Mode
UVVIO_R
VIO Rising
1.8
Undervoltage Detection on VIO for
Protected Mode
UVVIO_F
VIO Falling
0.8
1.7
100
150
-
-
V
Hysteresis Voltage on UVVIO for
Protected Mode (1)
VHYS_UVVIO
ꢀ
-
-
mV
µA
Normal mode, VTXD = 0 V,
Dominant
500
IIO
Supply Current from VIO
Normal/Silent mode, VTXD
VIO, Recessive
=
-
-
2
2
4
4
µA
µA
Standby/Sleep mode
Pin VBAT (Supply from battery)
Undervoltage Recovery on VBAT for
UVBAT_R
VBAT rising
-
3.5
4.3
V
Protected Mode
Undervoltage Detection on VBAT for
UVBAT_F
VBAT falling
3
-
3.3
-
-
V
Protected Mode
(1)
VHYS_UVBAT Hysteresis Voltage on UVBAT
ꢀ
200
mV
www.3peak.com
7 / 26
CA20230204A1