TPC/LR-50-XS series
Voltage regulation accuracy@-30~70
Line regulation@-30~70
Load regulation@-30~70
Temp. coefficient@-25~70
℃
±
±
±
±
≤
≥
3%
℃
0.5%
1%
℃
℃
0.03%/℃
Set-up time@25
℃
1S /230Vac full load
Hold-up time@25
℃
15mS(230Vac input, Full load)
Overshoot&Undershoot@-30~70
℃
<5.0%
INPUT CHARACTERISTICS
Conditions
Parameter
Input voltage range
Max. input voltage
Rated input voltage range
Frequency Range
90Vac~264Vac
300Vac input,no damage
100Vac~240Vac
47Hz~63Hz
,
dwell time 5000 mS
Set-up voltage@-30~70
Input current@25
Inrush current @25
Standby power@25
℃
90Vac(refer to the derating curve)
℃
<1A@115Vac
℃
50A@230Vac Cold start
℃
<0.5W
PROTECTION @-30~70℃
Conditions
Parameter
Notes
Over-power
(
5Voutput)
55W~90W
Over-power
Over-power
Over-power
Over-power
Over-power
(
(
(
(
(
12Voutput
15Voutput
24Voutput
36Voutput
48Voutput
)
)
)
)
)
)
55.5W~90W
56.5W~90W
58W~90W
110%~180% rated power, hiccup mode, auto recovery
57.4W~90W
58W~90W
Over-voltage
Over-voltage
Over-voltage
Over-voltage
Over-voltage
Over-voltage
(
5Voutput
5.75V~6.9V
13.8V~16.2V
18.75V~21.75V
28.8V~33.6V
41.4V~48.6V
55.2V~64.8V
11A~18A
(
(
(
(
(
12Voutput
15Voutput
24Voutput
36Voutput
48Voutput
)
)
)
)
)
110%~180% rated current, hiccup mode, auto recovery
Over-current
Over-current
(
(
5Voutput)
12Voutput
)
)
4.62A~7.5A
3.74A~6A
Over-current
(
15Voutput
115%~150% rated voltage, hiccup mode, auto recovery
Over-current
Over-current
Over-current
(
(
(
24Voutput
36Voutput
48Voutput
)
)
)
2.42A~3.75A
1.6A~2.5A
1.21A~1.875A
Output short circuit protection
Long-term mode, Auto recovery
ENVIRONMENT CHARACTERISTICS
Conditions
Parameter
Operating amb. Temp.&Humi.
Storage Temp. & Humi.
Vibration
-30
-40
℃
℃
~70
~85
℃
℃
;
;
20%~90%RH No condensing
10%~95%RH No condensing
(refer to the derating curve)
10 ~ 500Hz, 5G 10min./1cycle, period for60min. each along X,Y, Z axes
Pulse
20G/11mS pulse ,3 times at each X,Y,Z axes
5000m
Altitude
www.gztoppower.com
TEL:0086-20-82019000
Email:sales2@gztoppower.com
Page 2 / 5