100W Single Output Switching Power Supply
TOP100 Series 60-96 WATT AC/DC SWITCHPINGLPNOW-1ER0S0UPsPeLrIiEeSs
T
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
2 years warranty
110
SELV
EQUIVALENT
F
M
M
( for 48V only)
( except for 48V )
IP64
LPS
SPECIFICATION
MODEL
P/N
PLN-100-12
TOP100-12
12V
PLN-100-15
TOP100-15
15V
PLN-100-20
TOP100-20
20V
PLN-100-24
TOP100-24
24V
PLN-100-27
TOP100-27
27V
PLN-100-36
TOP100-36
36V
PLN-100-48
TOP100-48
48V
DC VOLTAGE
CONSTANT CURRENT REGION Note.7 6 ~ 12V
7.5 ~ 15V
5A
10 ~ 20V
4.8A
12 ~ 24V
4A
13.5 ~ 27V
3.55A
18 ~ 36V
2.65A
24 ~ 48V
2A
RATED CURRENT
CURRENT RANGE
RATED POWER
Note.6 5A
Note.6 0 ~ 5A
Note.6 60W
0 ~ 5A
75W
0 ~ 4.8A
96W
0 ~ 4A
96W
0 ~ 3.55A
95.85W
0 ~ 2.65A
95.4W
0 ~ 2A
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
0% ~ -15%. Can be adjusted by internal potential meter SVR1
3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
60ms/230VAC 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
PF>0.95/230VAC
83%
PF>0.95/115VAC at full load
85% 87%
15V:0.9A/115VAC 0.45A/230VAC
INPUT
87%
87%
87%
87%
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
0.5mA / 240VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC
95 ~ 100%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90 10 (RTH2)
52 ~ 64V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
I/P-O/P:4.25KVDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A
303.1Khrs min. MIL-HDBK-217F (25
200*70.5*35mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.52Kg; 20pcs/11.4Kg/0.76CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-100-SPEC 2008-08-18