TGL2210-SM
®
0.05ꢀ–ꢀ6.0 GHz 100 Watt VPIN Limiter
Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Min Typ Max Units
Parameter
Rating
Incident Power, Pulsed (PW = 10µs, DC
= 10%), 50 , 85 °C
Operating Temperature Range -40
+25
+85
°C
110 W
Passive – No Bias
85 W
70 W
Incident Power, CW, 50 , 25 °C
Electrical specifications are measured at specified test conditions.
Specifications are not guaranteed over all recommended operating
conditions.
Incident Power, CW, 50 , 85 °C
Mounting Temperature
(30 s max)
260 °C
Storage Temperature
-55 to 150 °C
Exceeding any one or a combination of the Absolute Maximum Rating
conditions may cause permanent damage to the device. Extended
application of Absolute Maximum Rating conditions to the device may
reduce device reliability.
Electrical Specifications
Parameter
Conditions
Min
Typical
Max
6.0
Units
GHz
dB
Operational Frequency Range
Insertion Loss, Un-Tuned
Insertion Loss, Tuned
0.05
Freq = 3.5 GHz
Freq = 3.5 GHz (1)
0.6
0.4
0.85
dB
dB
Input Return Loss, Un-Tuned
Output Return Loss, Un-Tuned ꢀ
Flat Leakage Power
10
10
11
dB
11.5
< 17
< 40
< 0.5
0.001
dBm
ns
@ PIN > 30 dBm
Pulse Recovery Time
dB
Spike Leakage
dB/ °C
Insertion Loss Temperature Coefficient
Notes: Test conditions unless otherwise noted: Tempꢀ=ꢀ+25ꢀ°C, 50ꢀΩ system.
1. Tuned EVB to improve 2-5 GHz
Thermal and Reliability Information
Parameter
Test Conditions
Value
Units
W
31
4.5 GHz, CW, 50 , 25 °C
Incident Power
(168 hours RF Operational Life Test (1)
)
100
W
4.5 GHz, Pulsed, PW=10 µs, DC=10%, 50 , 25 °C
Notes:
1. Test was terminated at 168 hours. Insertion Loss remained ≤ 1 dB for device under test.
Data Sheet Rev. B, October 2, 2018 | Subject to change without notice
2 of 10
www.qorvo.com