HIGH-ENERGY TRIGGERED SPARK GAPS

TG-221 数据手册

 浏览型号TG-221的Datasheet PDF文件第1页浏览型号TG-221的Datasheet PDF文件第2页 
HIGH-ENERGY TRIGGERED SPARK GAPS  
Triggergaps  
SPECIFICATIONS  
All characteristics at 25˚C  
TG-221  
TG-222  
TG-224  
PARAMETER  
CONDITIONS  
SYMBOL MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS  
Device Specifications  
Self-Breakdown Voltage  
Applied Voltage  
100V/s  
EZ  
1.0  
0.5  
-
-
20.0 18.0  
18.0 15.0  
-
40.0 1.0  
35.0 0.5  
-
20.0  
kV  
kV  
inches  
inches  
Ebb  
-
-
-
19.0  
-
Dimension A  
2.25  
2.50  
-
-
-
-
3.25  
2.50  
-
-
-
-
3.00  
4.50  
-
-
Dimension B  
-
-
Life Ratings  
Peak Current  
Discharge Life3  
PW=30µs  
1000 shots into 1Ω  
-
-
20  
3000  
-
-
-
-
20  
3000  
-
-
-
-
50  
6000  
-
-
-
-
kA  
J
TG-225  
TG-226  
PARAMETER  
CONDITIONS  
SYMBOL MIN TYP MAX MIN TYP MAX UNITS  
Device Specifications  
Self-Breakdown Voltage  
AppliedVoltage  
100V/s  
EZ  
18.0  
-
40.0 35.0  
35.0 30.0  
-
60.0  
kV  
Ebb  
15.0  
-
-
55.0  
kV  
-
Dimension A  
-
-
3.50  
4.50  
-
-
-
-
4.50  
4.50  
-
-
inches  
inches  
Dimension B  
-
Life Ratings  
Peak Current  
Discharge Life3  
PW=30µs  
1000 shots into 1Ω  
-
-
50  
6000  
-
-
-
-
50  
6000  
-
-
-
-
kA  
J
1 The trigger voltages given in these tables are the minimum triggering voltages necessary for triggering at the corresponding applied voltage limits. As the applied trigger voltage  
increases, the trigger voltage required for triggering decreases. It is assumed that the trigger is applied across the trigger and adjacent main electrodes — higher trigger voltages are  
required if it is applied across the trigger voltage and opposite main electrodes.  
2 End point for life testing is a 15% reduction in the self-breakdown voltage.  
3 Because the self-breakdown voltage of these devices is adjustable, the trigger voltage required for any particular applied voltage cannot be specified. Clare suggests setting the self-  
breakdown voltage to at least 115% of the maximum applied voltage.  
MECHANICAL DIMENSIONS  
ORDERING INFORMATION  
DIMENSIONS  
TA SERIES  
Triggergaps with self-breakdown voltages other than the standard val-  
ues listed (in the ranges of 1-15kV for the TA series and 2.5-25kV for the  
TB series) are available upon request.  
mm  
(inches)  
11.11 MAX.  
(0.438)  
A
A complete part number is represented by the digits below. Self-break-  
down voltages are expressed in kV. For example, TA-5.0 is a 5kV TA  
series device and TB-25.0 is a 25kV TB series device. The TG-221  
to 226 are ordered by the appropriate part number as given in the  
specifications.  
16.67 ± 0.79 DIA.  
(0.656 ± 0.031)  
25.40 ± 1.59  
(1.000 ± 0.063)  
1.59 DIA. TYP.  
(0.063)  
TA- X.X  
TA- XX.X  
TB- X.X  
TB- XX.X  
for 1.0-9.0kV  
for 10.0-15.0kV  
for 2.5-9.0kV  
for 10.0-25.0kV  
12.70 ± 1.59  
(0.500 ± 0.063)  
4.76 ± 1.59  
(0.188 ± 0.063)  
TB SERIES  
Series  
TA  
Self-breakdown voltage  
See specification tables  
C
B
TB  
ADJACENT  
TRIGGER  
OPPOSITE  
A DIA.  
North America: 1-800-CPCLARE  
Europe: 32-11-300868  
Asia: 886-2-2523-6368  
Japan: 81-3-3980-2212  
560  

与TG-221相关器件

型号 品牌 描述 获取价格 数据表
TG2210FT TOSHIBA RF SPDT Switch

获取价格

TG2211FT TOSHIBA TOSHIBA GaAs Linear Integrated Circuit GaAs Monolithic

获取价格

TG2213S TOSHIBA TOSHIBA GaAs Linear Integrated Circuit GaAs Monolithic

获取价格

TG2216TU TOSHIBA TOSHIBA GaAs Linear Integrated Circuit GaAs Monolithic

获取价格

TG2217CTB TOSHIBA RF/Microwave Switch, 1000 MHz - 2500 MHz RF/MICROWAVE DIVERSITY SWITCH, 0.75 dB INSERTION

获取价格

TG-222 CLARE HIGH-ENERGY TRIGGERED SPARK GAPS

获取价格