VI TELEFILTER
Resonator specification
TFR 315B
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
25
0
°C
dBm
50
50
Ω
Ω
Output:
Characteristics
Remark:
The minimum of the pass band attenuation a
is defined as the insertion loss a . The centre frequency f is the frequency of the minimum of the
e C
min
passband attenuation amin. The tolerance for the centre frequency also includes a frequency shift due to the temperature coefficient of frequency TC in the
operating temperature range and a production tolerance for the centre frequency f
f
.
C
D a t a
typ. value
tolerance / limit
a
= a
-
max.
2,5
dB
Insertion loss
(reference level)
e
min
fC
315,15
-
MHz
±100
kHz
Centre frequency
max.
-40/+10 ppm/yr
Ageing of centre frequency
(Absolute value during the first year)
Unloaded Q
8400
2000
3,8
27
117
2,1
-
-
-
-
-
-
-
Quality factor
Loaded Q 50ꢀ
C0
R1
L1
pF
ꢀ
Parallel capacitance
Motional resistance
Motional inductance
Motional capacitance
DC insulation resistance
Permissible DC voltage
Input power level
µH
fF
C1
min.
max.
max.
1
12
0
Mꢀ
V
VDC
-
-
dBm
OTR
T0
-
-
-10 °C ... + 60°C
-40 °C ... + 85°C
Operating temperature range
Storage temperature range
25
°C
max.
± 15
°C
Turnover temperature
TC **
0,035 ppm/K2
Temperature coefficient of frequency
f
*) The equivalent circuit model is for reference only.
**) ∆f(Hz) = TC (ppm/K²) x (T0-T)² x f
(MHz).
CAT
f
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.