TC74AC139P/F/FN/FT
Electrical Characteristics
DC Characteristics
Ta =
−40 to 85°C
Ta = 25°C
Test Condition
Characteristics
Symbol
Unit
V
V
(V)
CC
Min
Typ.
Max
Min
Max
2.0
1.50
2.10
3.85
―
―
―
―
―
1.50
2.10
3.85
―
―
―
High-level input
voltage
V
―
―
3.0
5.5
2.0
3.0
5.5
2.0
3.0
4.5
3.0
4.5
IH
―
―
―
―
0.50
0.90
1.65
―
0.50
0.90
1.65
―
Low-level input
voltage
V
―
―
―
V
V
IL
―
―
―
1.9
2.9
4.4
2.58
3.94
―
2.0
3.0
4.5
―
1.9
2.9
4.4
2.48
3.80
3.85
―
I
= −50 μA
―
―
OH
V
IN
IH
IL
―
―
High-level output
voltage
V
= V or
V
OH
I
I
I
= −4 mA
―
―
OH
OH
OH
= −24 mA
―
―
―
= −75 mA (Note) 5.5
―
―
―
2.0
―
0.0
0.0
0.0
―
0.1
0.1
0.1
0.36
0.36
―
0.1
0.1
0.1
0.44
0.44
1.65
I
= 50 μA
3.0
4.5
―
―
OL
V
IN
IH
IL
―
―
Low-level output
voltage
V
= V or
V
V
OL
I
I
I
= 12 mA
= 24 mA
= 75 mA
3.0
―
―
OL
OL
OL
4.5
―
―
―
(Note) 5.5
―
―
―
Input leakage
current
I
V
V
= V
= V
or GND
or GND
5.5
5.5
―
―
―
―
±0.1
8.0
―
―
±1.0
80.0
μA
μA
IN
IN
IN
CC
Quiescent supply
current
I
CC
CC
Note:
This spec indicates the capability of driving 50 Ω transmission lines.
One output should be tested at a time for a 10 ms maximum duration.
AC Characteristics (C = 50 pF, R = 500 Ω, input: t = t = 3 ns)
L
L
r
f
Ta =
−40 to 85°C
Test Condition
Ta = 25°C
Typ.
Characteristics
Symbol
Unit
ns
V
(V)
Min
Max
Min
Max
CC
Propagation delay
time
t
t
3.3 ± 0.3
5.0 ± 0.5
―
―
8.2
6.2
13.9
9.0
1.0
1.0
16.0
10.3
pLH
―
pHL
(A, B- Y )
Propagation delay
time
t
t
3.3 ± 0.3
5.0 ± 0.5
―
―
7.6
5.8
12.9
8.5
1.0
1.0
14.8
9.6
pLH
―
ns
pHL
( G - Y )
Input capacitance
C
―
―
―
5
10
―
―
10
pF
pF
IN
Power dissipation
capacitance
C
PD
(Note)
110
―
―
Note:
C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
I
= C ·V ·f + I /2 (per decoder)
PD CC IN CC
CC (opr)
4
2007-10-01