Power entry modules without line filter
6ꢀ35
www.schurter.com/pg05
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In 3 ... 15 A
>
[ min ] [ sec ]
10'000
[ min ] [ sec ]
10'000
Type
p
TA35
Type
TA35
>
3–15A (TC-1, TC-2)
Rated current
<3A (TC-1, TC-2)
+23 °C
Rated current
Ambient temp.
Ambient temp. +23 °C
60
60
2`000
1`000
500
2`000
30
30
20
20
1`000
10
5
10
500
5
200
100
50
200
100
1
1
50
20
20
10
5
10
5
2
2
1
1
0,5
0,5
0,3
0,2
0,3
0,2
0,1
0,1
1,05 1,35
2
3
4
5
8
10
]
1,05 1,35
2
3
4
5
8
10
]
Multiple of rated current
Multiple of rated current
[ x I
[ x I
n
n
The above tripping characteristics apply to symmetrical overloads on the two poles.
At asymmetric overloads on two pole types the tripping current will be increased by factor 1.05 (TC-2).
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for lower or higher ambient temperature,
use a correction factor from the table below.
* Temperature must be measured at the rear of the breaker
next to the terminals after equipment operating tempera-
ture has been reached.
* Ambient
temperature [°C]
Correction factor
Example:
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at +60 °C
ambient temperature:
10 A
+60 °C
1.06
–25
–20
0
0.79
0.81
0.90
1.00
1.03
1.04
1.06
10 A x 1.06 = 10.6 A
+23
+40
+50
+60
Order code (Order example)
Wiring
1 wired
Type
Order code TA35
0 unwired
Terminals
1 Quick connect 6.3 x 0.8 mm
6135
C B D W F 1 2 0 C 0
. 0 2 1 0
Mounting
see table 1
2 Snap-in s = 1.5 mm
3 Snap-in s = 2.0 mm
4 Snap-in s = 2.5 mm
5 Snap-in s = 3.0 mm
Please note that Schurter will establish an
internal part number for logistics use in
addition to the order code. The format of
this internal part number is, for example:
6135.xxxx.xxxx
0 Protection class 1
40ꢀPcsꢀ
Packaging unit
Connectors
ꢂ