Figure 1. Nomenclature and Order Guide
_
_ _ _ _ _ _ _ _
_
_
A
SSC
Supply Voltage
3 = 3.3 Vdc
Series
5 = 5.0 Vdc
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Transfer Function11
A = 10% to 90% of Vsupply
Output Type12
S = SPI (not available in SIP package)
2 = I2C, Address 0x28
3 = I2C, Address 0x38
4 = I2C, Address 0x48
5 = I2C, Address 0x58
6 = I2C, Address 0x68
7 = I2C, Address 0x78
Pressure Port (* indicates not available)
SMT
DIP
SIP
NN = No ports
NN = No ports
NN = No ports
Pressure Range13, 14
AA = Dual axial
barbed ports,
opposite sides
*
*
1 psi to 150 psi
60 mbar to 10 bar
Absolute
AN = Single
axial barbed
port
AN = Single
axial barbed
port
AN = Single
axial barbed
port
015PA = 0 psi to 15 psi
030PA = 0 psi to 30 psi
060PA = 0 psi to 60 psi
100PA = 0 psi to 100 psi
150PA = 0 psi to 150 psi
Absolute
001BA = 0 bar to 1 bar
1.6BA = 0 bar to 1.6 bar
2.5BA = 0 bar to 2.5 bar
004BA = 0 bar to 4 bar
006BA = 0 bar to 6 bar
010BA = 0 bar to 10 bar
LN = Single
axial barbless
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
Differential
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
060PD = ±60 psi
FF = Fastener
mount, dual axial
barbed ports,
opposite sides
Differential
060MD = ±60 mbar
100MD = ±100 mbar
160MD = ±160 mbar
250MD = ±250 mbar
400MD = ±400 mbar
600MD = ±600 mbar
001BD = ±1 bar
*
*
FN = Fastener
mount, single axial
barbed port
Gage
001PG = 0 psi to 1 psi
005PG = 0 psi to 5 psi
015PG = 0 psi to 15 psi
030PG = 0 psi to 30 psi
060PG = 0 psi to 60 psi
100PG = 0 psi to 100 psi
150PG = 0 psi to 150 psi
*
*
*
*
*
1.6BD = ±1.6 bar
2.5BD = ±2.5 bar
004BD = ±4 bar
GN = Ribbed
fastener mount,
single axial
barbed port
Gage
NB = Fastener
mount, dual axial
ports, same side
060MG = 0 mbar to 60 mbar
100MG = 0 mbar to 100 mbar
160MG = 0 mbar to 160 mbar
250MG = 0 mbar to 250 mbar
400MG = 0 bar to 400 mbar
600MG = 0 bar to 600 mbar
001BG = 0 bar to 1 bar
1.6BG = 0 bar to 1.6 bar
2.5BG = 0 bar to 2.5 bar
004BG = 0 bar to 4 bar
006BG = 0 bar to 6 bar
010BG = 0 bar to 10 bar
*
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
DR =Dual radial
barbed ports,
opposite sides
DR = Dual radial
barbed ports,
opposite sides
Options15
N = Dry gases only, no special options
D = Dry gases only, diagnostics on
T = Liquid media on port 1, no diagnostics
V = Liquid media on port 1, diagnostics on
HH = Fastener
mount, dual
radial barbed
ports, same side
*
*
*
*
HN = Fastener
mount, single
radial barbed
port
MN = Manifold
mount, outer
diameter seal
*
*
*
*
SN = Manifold
mount, inner
diameter seal
Notes:
11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and
Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other
transfer functions are available. Contact Honeywell Customer Service for more information.
12. Analog output is also available. Contact Honeywell Customer Service for more information.
13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information.
14. See Table 5 for an explanation of sensor pressure types.
15. See CAUTION on previous page.
4
www.honeywell.com/sensing