5秒后页面跳转
SSCDNND600MDAA3 PDF预览

SSCDNND600MDAA3

更新时间: 2024-01-14 22:08:32
品牌 Logo 应用领域
霍尼韦尔 - HONEYWELL 传感器换能器
页数 文件大小 规格书
12页 1130K
描述
Peizoresistive Sensor, Differential, -8.7Psi Min, 8.7Psi Max, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, DIP-8

SSCDNND600MDAA3 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:ActiveReach Compliance Code:unknown
风险等级:5.75最大精度 (%):0.25%
其他特性:TEMPERATURE COMPENSATED OVER -20 TO 85 DEG主体宽度:10 mm
主体高度:5.54 mm主体长度或直径:13.35 mm
外壳:CERAMIC安装特点:THROUGH HOLE MOUNT
最大工作电流:2.1 mA最高工作温度:85 °C
最低工作温度:-40 °C输出接口类型:I2C INTERFACE
输出类型:ANALOG VOLTAGE封装形状/形式:RECTANGULAR
端口类型:HOLE最大压力范围:8.7 Psi
最小压力范围:-8.7 Psi压力传感模式:DIFFERENTIAL
响应时间:1000 µs传感器/换能器类型:PRESSURE SENSOR,PIEZORESISTIVE
最大供电电压:3.6 V最小供电电压:3 V
表面贴装:NO端接类型:SOLDER
Base Number Matches:1

SSCDNND600MDAA3 数据手册

 浏览型号SSCDNND600MDAA3的Datasheet PDF文件第1页浏览型号SSCDNND600MDAA3的Datasheet PDF文件第2页浏览型号SSCDNND600MDAA3的Datasheet PDF文件第4页浏览型号SSCDNND600MDAA3的Datasheet PDF文件第5页浏览型号SSCDNND600MDAA3的Datasheet PDF文件第6页浏览型号SSCDNND600MDAA3的Datasheet PDF文件第7页 
Table 3. Environmental Specifications  
Parameter  
Characteristic  
Humidity:  
Dry gases only (See “Options N and D” in Figure 1.)  
Liquid media (See “Options T and V” in Figure 1.)  
0% to 95% RH, non-condensing  
100% condensing or direct liquid media on Port 1  
MIL-STD-202F, Curve AK (20.7 g random)  
MIL-STD-202F, Method 213B, Condition F  
1 million cycles minimum  
Vibration  
Shock  
Life9  
Solder reflow  
J-STD-020-C  
Table 4. Wetted Materials10  
Parameter  
Covers  
Substrate  
Port 1 (Pressure Port)  
high temperature polyamide  
alumina ceramic  
Port 2 (Reference Port)  
high temperature polyamide  
alumina ceramic  
Adhesives  
epoxy, silicone  
epoxy, silicone  
Electronic components  
Notes:  
ceramic, glass, solder, silicon  
silicon, glass, gold, solder  
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.  
2. Ratiometricity of the sensor (the ability of the device to scale to the supply voltage) is achieved within the specified operating voltage for each  
option.  
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.  
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within  
the specified performance limits.  
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not  
remain within the specified performance limits.  
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at  
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.  
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.  
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal  
effect on span, and thermal hysteresis.  
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of  
the pressure range. (See Figure 1 for ranges.)  
9. Life may vary depending on specific application in which sensor is utilized.  
10. Contact Honeywell Customer Service for detailed material information.  
CAUTION  
PRODUCT DAMAGE  
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.  
Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate  
inside the sensor, causing damage or affecting sensor output.  
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to  
enter and settle within the pressure sensor if it is in this position.  
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a  
dead-ended sensor is difficult and has limited effectiveness for removing residue.  
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and  
may lead to sensor failure.  
Failure to comply with these instructions may result in product damage.  
Honeywell Sensing and Control  
3

与SSCDNND600MDAA3相关器件

型号 品牌 描述 获取价格 数据表
SSCDNND600MDAA5 HONEYWELL Peizoresistive Sensor, Differential, -8.7Psi Min, 8.7Psi Max, 0.25%, Rectangular, Through

获取价格

SSCDNND600MDAB3 HONEYWELL Peizoresistive Sensor, Differential, 0Psi Min, 8.7Psi Max, 0.25%, Rectangular, Through Hol

获取价格

SSCDNND600MDSA3 HONEYWELL Peizoresistive Sensor, Differential, -8.702Psi Min, 8.702Psi Max, 0.25%, Rectangular, Thro

获取价格

SSCDNND600MDSA5 HONEYWELL Peizoresistive Sensor, Differential, -8.702Psi Min, 8.702Psi Max, 0.25%, Rectangular, Thro

获取价格

SSCDNND600MG4A3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 8.702Psi Max, 0.25%, 0.20-0.80V, Rectangular, Throu

获取价格

SSCDNND600MG5A3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 8.702Psi Max, 0.25%, 0.20-0.80V, Rectangular, Throu

获取价格