5秒后页面跳转
SSCDNND150PASA5 PDF预览

SSCDNND150PASA5

更新时间: 2024-02-07 19:24:29
品牌 Logo 应用领域
霍尼韦尔 - HONEYWELL 传感器换能器压力传感器
页数 文件大小 规格书
12页 1201K
描述
Peizoresistive Sensor, Absolute, 0Psi Min, 150Psi Max, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, DIP-8

SSCDNND150PASA5 技术参数

是否Rohs认证:符合生命周期:Active
Reach Compliance Code:unknown风险等级:5.69
Is Samacsys:N最大精度 (%):0.25%
外壳:CERAMIC安装特点:THROUGH HOLE MOUNT
位数:12最大工作电流:2.1 mA
最高工作温度:85 °C最低工作温度:-40 °C
输出接口类型:SPI INTERFACE输出类型:DIGITAL VOLTAGE
封装形状/形式:RECTANGULAR端口类型:STRAIGHT
最大压力范围:8.702 Psi最小压力范围:
压力传感模式:GAGE响应时间:460 µs
传感器/换能器类型:PRESSURE SENSOR,PEIZORESISTIVE最大供电电压:3.6 V
最小供电电压:3 V表面贴装:NO
端接类型:SOLDERBase Number Matches:1

SSCDNND150PASA5 数据手册

 浏览型号SSCDNND150PASA5的Datasheet PDF文件第1页浏览型号SSCDNND150PASA5的Datasheet PDF文件第2页浏览型号SSCDNND150PASA5的Datasheet PDF文件第4页浏览型号SSCDNND150PASA5的Datasheet PDF文件第5页浏览型号SSCDNND150PASA5的Datasheet PDF文件第6页浏览型号SSCDNND150PASA5的Datasheet PDF文件第7页 
Table 3. Environmental Specifications  
Parameter  
Characteristic  
Humidity:  
Dry gases only (See “Options N and D” in Figure 1.)  
Liquid media (See “Options T and V” in Figure 1.)  
0% to 95% RH, non-condensing  
100% condensing or direct liquid media on Port 1  
MIL-STD-202F, Curve AK (20.7 g random)  
MIL-STD-202F, Method 213B, Condition F  
1 million cycles minimum  
Vibration  
Shock  
Life9  
Solder reflow  
J-STD-020-C  
Table 4. Wetted Materials10  
Parameter  
Covers  
Port 1 (Pressure Port)  
high temperature polyamide  
alumina ceramic  
Port 2 (Reference Port)  
high temperature polyamide  
alumina ceramic  
Substrate  
Adhesives  
epoxy, silicone  
epoxy, silicone  
Electronic components  
Notes:  
ceramic, glass, solder, silicon  
silicon, glass, gold, solder  
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.  
2. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved  
within the specified operating voltage for each option.  
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.  
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within  
the specified performance limits.  
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not  
remain within the specified performance limits.  
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at  
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.  
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.  
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal  
effect on span, and thermal hysteresis.  
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of  
the pressure range. (See Figure 1 for ranges.)  
9. Life may vary depending on specific application in which sensor is utilized.  
10. Contact Honeywell Customer Service for detailed material information.  
CAUTION  
PRODUCT DAMAGE  
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.  
Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate  
inside the sensor, causing damage or affecting sensor output.  
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to  
enter and settle within the pressure sensor if it is in this position.  
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a  
dead-ended sensor is difficult and has limited effectiveness for removing residue.  
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and  
may lead to sensor failure.  
Failure to comply with these instructions may result in product damage.  
Honeywell Sensing and Control  
3

与SSCDNND150PASA5相关器件

型号 品牌 描述 获取价格 数据表
SSCDNND150PG2A3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through

获取价格

SSCDNND150PG2A5 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through

获取价格

SSCDNND150PG4A3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through

获取价格

SSCDNND150PG4A5 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through

获取价格

SSCDNND150PGAA3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, Rectangular, Through Hole Mount,

获取价格

SSCDNND150PGSA5 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 0.25%, Rectangular, Through Hole Mount,

获取价格