RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR
SR Series
ꢀ
FEATURES
◆
◆
Load life of 2000 hours at 85°C
High value of CV range
◆
◆
Standard series for general purpose
Applications for TV, video, audio, office and home appliances, etc.
ꢀ
OUTLINE
mm
25
D
F
d
5
6.3
8
10
13
16
18
20
22
5.0
7.5
10.5
2.0 2.5 3.5
0.5
12.5
1
0.6
0.8
ꢀ
SPECIFICATIONS
Items
Characteristics
Capacitance Tolerance
(120Hz, 25°C)
± 20% (M)
Rated Working Voltage Range
Operation Temperature
6.3 ~ 100Vdc
160 ~ 450Vdc
-25°C ~ +85°C
-40°C ~ +85°C
(After 2 minutes applying the DC working voltage)
(After 5 minutes applying the DC working voltage)
I ≤ 0.03CV + 10 (u A)
Leakage Current (25°C)
Surge Voltage (25°C)
I ≤ 0.01CV or 3 (u A)
◆ I : Leakage Current (u A)
◆ C : Rated Capacitance (u F)
◆ V : Working Voltage (V)
W.V.
S.V.
6.3 10
13
6.3 10
16
20
16
25
32
25
35
44
35
40
50
40
50
63 100 160 200 250 350 400 450
79 125 200 250 300 400 450 500
63 100 160 200 250 350 400 450
8
63
W.V.
tan δ
50
Dissipation Factor (120Hz, 25°C)
0.25 0.20 0.17 0.15 0.12 0.12 0.10 0.10 0.10 0.15 0.15 0.15 0.20 0.20 0.20
◆ For capacitance exceeding 1000 u F, add 0.02 per increment of 1000 u F
W.V.
6.3 10
16
3
25
3
35
2
40
2
50
2
63 100 160 200 250 350 400 450
- 25°C / + 25°C
- 40°C / + 25°C
4
4
8
2
3
2
3
3
4
3
4
3
4
6
6
6
6
6
6
Temperature Characteristics
10
6
4
3
3
3
◆ Impedance ratio at 120Hz
After 2000 hours application of WV at +85°C, the capacitor shall meet the following limits:
Capacitance Change
tan δ
≤ ± 20% of initial value
Load Test
≤ 150% of initial specified value
≤ initial specified value
Leakage Current
After 1000 hours, no voltage applied at +85°C, the capacitor shall meet the following limits:
Capacitance Change
tan δ
≤ ± 20% of initial value
Shelf Test
≤ 150% of initial specified value
≤ 200% of initial specified value
Leakage Current
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Qubec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com