Rated
Peak
40W
56W
General Purpose
SNP-G04 Series
Output Specifications:
MODEL
OUTPUT
RAIL
LOAD
VOLTAGE
RIPPLE
NOISE
LINE
REG.
LOAD
REG.
NO.
ACCURACY
MIN.
RATED MAX.
PEAK
SNP-G047
SNP-G047 -M
+12V
+15V
+18V
+24V
+28V
+36V
+48V
0A 3.33A
0A 2.66A
0A 2.22A
0A 1.66A
0A 1.42A
0A 1.11A
0A 0.83A
4.7A
+11.8V~+12.2V
+14.8V~+15.2V
+17.8V~+18.2V
+23.7V~+24.3V
+27.7V~+28.2V
+35.6V~+36.4V
+47.6V~+48.4V
100mVpp
100mVpp
100mVpp
150mVpp
150mVpp
150mVpp
150mVpp
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
SNP-G048
SNP-G048 -M
3.8A
3.2A
2.4A
2.0A
1.6A
1.16A
SNP-G045
SNP-G045 -M
SNP-G049
SNP-G049 -M
SNP-G04G
SNP-G04G-M
SNP-G04J
SNP-G04J -M
SNP-G04T
SNP-G04T-M
Note:
1. Standby Power Cosumption with System:
For computers and displays, ENERGY STAR in U.S. and ErP regulation in Europe require the input power should be less than 0.5W at standby mode.
2. Output Load:
40W for convection cooling.
3. Peak Load Duration:
Peak 56W can last for 5 sec.
4.
Isolation G←r→ade:
Primary
Primary
Ground
: 1MOPP (1500Vac)
Secondary : 2MOPP (4000Vac)
: 1MOPP (1500Vac)
←→
Secondary ←→ Ground
5. Leakage Current:
Earth leakage current < 300uA
Touch current < 100uA
6. EMI Grounding:
If there is a metal sheet under the power supply, connect the EMI ground to the metal sheet.
7. Model Selection:
SNP-G04x is for ITE application.
SNP-G04x-M is for medical application.
-Jim-
** This data sheet is only for models selection. For business, engineering specification by model must be used.
4-2