TABLE 1
"B"
RFXXX-XXXXX-XXXXX-XXXX
REVISION G
STYLE
"A"
"C"
-01SP1
-01RP1
-01BJ1
-02SJ1
-02RP1
-02SP1
-03SP1
-03RP1
-13GP1
-13GJ1
-04SP1
-04BJ1
-05SP1
-05BJ1
-06BJ1
-07SP1
-07RP1
-07BJ1
-01BJR
3.10 [0.122] 2.00 [0.079] 5.50 [0.217]
1.50 [0.059] 3.00 [0.118] 5.50 [0.217]
3.50 [0.138] 2.50 [0.098] 6.00 [0.236]
3.10 [0.122] 2.30 [0.091] 4.50 [0.177]
1.30 [0.051] 1.80 [0.071] 4.50 [0.177]
2.50 [0.098] 1.00 [0.039] 5.00 [0.197]
2.20 [0.087] 2.60 [0.102] 4.50 [0.177]
1.30 [0.051] 2.00 [0.079] 4.80 [0.189]
2.20 [0.087] 2.60 [0.102] 4.50 [0.177]
2.20 [0.087] 2.60 [0.102] 4.50 [0.177]
3.40 [0.134] 4.50 [0.177] 8.50 [0.335]
4.50 [0.177] 6.20 [0.244] 8.00 [0.315]
4.90 [0.193] 3.00 [0.118] 9.50 [0.374]
4.50 [0.177] 6.20 [0.244] 8.00 [0.315]
4.70 [0.185] 7.70 [0.303] 6.50 [0.256]
2.10 [0.083] 1.70 [0.067] 5.50 [0.217]
1.40 [0.055] 3.10 [0.122] 5.00 [0.197]
2.50 [0.098] 2.60 [0.102] 5.00 [0.197]
2.50 [0.098] 3.70 [0.146] 6.00 [0.236]
DESIGNED & DIMENSIONED
IN MILLIMETERS[INCHES]
OVERALL CABLE LENGTH (SEE NOTE 8)
MILLIMETERS OF CABLE
0100 - 1100
CABLE CALL OUT
174: CCA-174
316: CCA-316
TABLE 2
STYLE SUBTRACTOR
DO NOT
SCALE FROM
THIS PRINT
-01SP1
-01RP1
-01BJ1
-02SJ1
-02RP1
-02SP1
-03SP1
-03RP1
-13GP1
-13GJ1
-SING
-04SP1
-04BJ1 12.35 [0.486]
-05SP1 8.85 [0.348]
-05BJ1 12.35 [0.486]
-06BJ1 16.70 [0.657]
-07SP1
-07RP1
-07BJ1
-01BJR
5.45 [0.215]
2.83 [0.111]
3.51 [0.138]
5.88 [0.231]
1.99 [0.078]
7.30 [0.287]
3.90 [0.154]
1.49 [0.059]
5.05 [0.199]
4.15 [0.163]
0.00 [0.000]
8.60 [0.339]
END 2 CONNECTOR CALL OUT
END 1 CONNECTOR CALL OUT
-01SP1: SMA-P-C-H-ST-CA1 (SEE SHEET 2)
-01RP1: SMA-P-C-H-RA-CA1 (SEE SHEET 2)
-01BJ1: SMA-J-C-H-ST-BH1 (SEE SHEET 2)
-02SJ1: MCX-J-C-H-ST-CA1 (SEE SHEET 2)
-02RP1: MCX-P-C-H-RA-CA1 (SEE SHEET 2)
-02SP1: MCX-P-C-H-ST-CA1 (SEE SHEET 2)
-03SP1: MMCX-P-C-H-ST-CA1 (SEE SHEET 2)
-03RP1: MMCX-P-C-H-RA-CA1 (SEE SHEET 2)
-SING: SINGLE ENDED (ONE END ONLY)
-04SP1: BNC5-P-C-G-ST-CA1 (SEE SHEET 4)
-04BJ1: BNC5-J-C-F-ST-BH1 (SEE SHEET 4)
-05SP1: TNC-P-C-G-ST-CA1 (SEE SHEET 4)
-05BJ1: TNC-J-C-F-ST-BH1 (SEE SHEET 4)
-06BJ1: NTPE-J-C-G-ST-CA1 (SEE SHEET 4)
-07SP1: SMB5-P-C-G-ST-CA1 (SEE SHEET 4)
-07RP1: SMB5-P-C-H-RA-CA1 (SEE SHEET 4)
-07BJ1: SMB5-J-C-H-ST-BH1 (SEE SHEET 4)
**-01BJR: SMA-J-C-X-ST-BR1 (SEE SHEET 4)
-01SP1: SMA-P-C-H-ST-CA1 (SEE SHEET 2)
-01RP1: SMA-P-C-H-RA-CA1 (SEE SHEET 2)
-01BJ1: SMA-J-C-H-ST-BH1 (SEE SHEET 2)
-02SJ1: MCX-J-C-H-ST-CA1 (SEE SHEET 2)
-02RP1: MCX-P-C-H-RA-CA1 (SEE SHEET 2)
-02SP1: MCX-P-C-H-ST-CA1 (SEE SHEET 2)
-03SP1: MMCX-P-C-H-ST-CA1 (SEE SHEET 2)
-03RP1: MMCX-P-C-H-RA-CA1 (SEE SHEET 2)
-04SP1: BNC5-P-C-G-ST-CA1 (SEE SHEET 4)
-04BJ1: BNC5-J-C-F-ST-BH1 (SEE SHEET 4)
-05SP1: TNC-P-C-G-ST-CA1 (SEE SHEET 4)
-05BJ1: TNC-J-C-F-ST-BH1 (SEE SHEET 4)
-06BJ1: NTPE-J-C-G-ST-CA1 (SEE SHEET 4)
-07SP1: SMB5-P-C-G-ST-CA1 (SEE SHEET 4)
-07RP1: SMB5-P-C-H-RA-CA1 (SEE SHEET 4)
-07BJ1: SMB5-J-C-H-ST-BH1 (SEE SHEET 4)
**-01BJR: SMA-J-C-X-ST-BR1 (SEE SHEET 4)
CABLE STRIPPING DIMS PER CONNECTOR
(SEE TABLE 1)
"A"
"C"
7.30 [0.287]
2.90 [0.114]
8.10 [0.319]
9.83 [0.387]
"B"
*-13GP1: GRF1-P-C-H-ST-CA1 (316 OPTION ONLY)
(SEE SHEET 2)
*-13GJ1: GRF1-J-C-H-ST-CA1 (316 OPTION ONLY)
(SEE SHEET 2)
*-13GP1: GRF1-P-C-H-ST-CA1 (316 OPTION ONLY)
(SEE SHEET 2)
*-13GJ1: GRF1-J-C-H-ST-CA1 (316 OPTION ONLY)
(SEE SHEET 2)
NOTES:
C
1. REPRESENTS A CRITICAL DIMENSION.
2. CABLE CUT LENGTH = OAL - SUBTRACTOR FOR END 1 - SUBTRACTOR FOR END 2.
(SEE TABLE 2 FOR SUBTRACTORS)
3. SEE SHEET 3, TABLE 4 FOR RECOMMENDED CRIMPED DIMENSION.
4. ASSEMBLY TO BE 100% TESTED FOR OPENS & SHORTS.
5. ASSEMBLY TO BE 100% HI-POT TESTED AT 300DVC.
** NOT RELEASED
* FOR INTERNAL USE ONLY
C3
C4
6. CRITICALS TO BE CHECKED IN PROCESS.
7. FINISHED ASSEMBLIES TO BE PACKAGED IN INDIVIDUAL POLY ZIPPER BAGS.
8. CABLE STOCKED IN INCHES, 1 INCH = 25.4 MILLIMETERS.
9. TO BE MEASURE FROM THE HIGHEST POINT ON THE SHELL TO THE HIGHEST
ON THE PIN.
7.80 .307 REF
10. FOR -RA TO -RA, CONNECTORS SHOULD BOTH BE ORIENTED UP. (SEE SHEET 2)
8.40 .331 REF
16.00 .630 REF
9.40 .370
REF
HST-XX
HST-XX
7.80 .307 REF
-01RP1
-01SP1
END 1
C1
END 2
LENGTH: XXXX
7.00 .276 SQ REF
(SEE TABLE 3 FOR TOL)
SEE NOTE 2 FOR CABLE CUT LENGTH
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN MM.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
.X:
.XX:
.XXX:
.3 [.01]
2
520 PARK EASTBLVD, NEW ALBANY, IN 47150
TABLE 3 (IN MILLIMETERS)
.13 [.005]
PHONE: 812-944-6733
FAX: 812-948-5047
code: 55322
.051 [.0020]
e-Mail: info@SAMTEC.com
LENGTH
TOLERANCE
SHEETSCALE: 2:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
RF316 OR RF174 CABLE ASSEMBLY
0100-0200 [3.92-7.87]
0200-0500 [7.87-19.69]
0500-1100 [19.69-43.30] +10.0 [.394]/-0.0 [.000]
+3.0 [.118]/-0.0 [.000]
+5.0 [.197]/-0.0 [.000]
FOR MATERIAL SEE
CONNECTOR PRINTS
DWG. NO.
RFXXX-XXXXX-XXXXX-XXXX
BY:
TIM P.
5/3/2005
SHEET1 OF 4
F:\DWG\MISC\MKTG\RFXXX-XXXXX-XXXXX-XXXX-MKT.SLDDRW