RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
RSG
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
ELECTRONIC COMPONENTS
Änderungen vorbehalten / subject to change without notice
65W Dual Output Switching Power Supply
RD-65 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
RD-65A
RD-65B
OUTPUT NUMBER
CH1
5V
CH2
12V
CH1
CH2
24V
DC VOLTAGE
5V
RATED CURRENT
CURRENT RANGE
RATED POWER
6A
3A
4A
2A
Note.6 0.3 ~ 8A
Note.6 66W
0.2 ~ 4A
0.3 ~ 8A
68W
0.2 ~ 3A
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
80mVp-p
CH1: 4.75 ~ 5.5V
2.0%
150mVp-p
OUTPUT
CH1: 4.75 ~ 5.5V
6.0%
+4,-6%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
Note.4 0.5%
Note.5 0.5%
1.5%
0.5%
3.0%
0.5%
4.0%
500ms, 20ms/230VAC
1200ms, 30ms/115VAC at full load
60ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
79%
14ms/115VAC at full load
VOLTAGE RANGE
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
78%
INPUT
2A/115VAC
1.2A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )on +5V output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
SAFETY &
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
EMC
(Note 7)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
MTBF
265.9Khrs min. MIL-HDBK-217F (25
129*98*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.44Kg; 30pcs/14.2Kg/0.72CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RD-65-SPEC 2005-09-13