RxxP2xxS_D/R
DC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage, full load)
Series
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
EN60950-1: 2006 + A2:2013
IEC60950-1-2005 , 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
LVD1605077-14
ANSI/UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1
2236395
2207629
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
UL60601-1, 1st Edition
CAN/CSA-C22.2 No. 601.1-M90
2207629
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
ANSI/AAMI ES60601-1:2005 +A2:10
CAN/CSA-C22.2 No. 60601-1:2008
E314885-A5-UL
E314885-A5-CB-1
WD-SE-R-180539-A0
Medical Electric Equipment, General Requirements for Safety and
Essential Performance. (CB Scheme)
IEC60601-1:2005 + C2:2007
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
EN60601-1:2006 + A12:2014
IEC60601-1:2005 + A1:2012, 3rd Edition
Safety requirements for electrical equipement for measurement, control
and laboratory use
EN61010:2010
IEC61010:2010, 3rd Edition
T1301251-313
RU-AT.37.02367
EAC
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(refer to “EMC Filtering”)
EN55032, Class A and B
continued on next page
REV.: 6/2020
www.recom-power.com
ECO-4