5秒后页面跳转
QT118H-IG PDF预览

QT118H-IG

更新时间: 2024-02-03 16:27:19
品牌 Logo 应用领域
昆腾 - QUANTUM 传感器
页数 文件大小 规格书
14页 422K
描述
CHARGE-TRANSFER TOUCH SENSOR

QT118H-IG 技术参数

是否Rohs认证: 不符合生命周期:Obsolete
包装说明:,Reach Compliance Code:unknown
风险等级:5.92Base Number Matches:1

QT118H-IG 数据手册

 浏览型号QT118H-IG的Datasheet PDF文件第1页浏览型号QT118H-IG的Datasheet PDF文件第2页浏览型号QT118H-IG的Datasheet PDF文件第4页浏览型号QT118H-IG的Datasheet PDF文件第5页浏览型号QT118H-IG的Datasheet PDF文件第6页浏览型号QT118H-IG的Datasheet PDF文件第7页 
1.3 ELECTRODE DESIGN  
Figure 1-3 Internal Switching & Timing  
ELECTRODE  
1.3.1 ELECTRODE  
G
EOMETRY AND  
S
IZE  
Result  
There is no restriction on the shape of  
the electrode; in most cases common  
sense and a little experimentation can  
result in a good electrode design. The  
QT118H will operate equally well with  
long, thin electrodes as with round or  
square ones; even random shapes are  
acceptable. The electrode can also be  
a 3-dimensional surface or object.  
Sensitivity is related to electrode  
surface area, orientation with respect  
to the object being sensed, object  
composition, and the ground coupling  
quality of both the sensor circuit and  
the sensed object.  
SNS2  
Cs  
Start  
Cx  
Done  
SNS1  
C harge  
Amp  
1.3.2 KIRCHOFF  
S  
CURRENT  
LAW  
Like all capacitance sensors, the  
QT118H relies on Kirchoffs Current  
Law (Figure 1-5) to detect the change  
crumpled into a ball. Virtual ground planes are more effective  
and can be made smaller if they are physically bonded to  
other surfaces, for example a wall or floor.  
in capacitance of the electrode. This law as applied to  
capacitive sensing requires that the sensors field current  
must complete a loop, returning back to its source in order for  
capacitance to be sensed. Although most designers relate to  
Kirchoffs law with regard to hardwired circuits, it applies  
equally to capacitive field flows. By implication it requires that  
the signal ground and the target object must both be coupled  
together in some manner for a capacitive sensor to operate  
properly. Note that there is no need to provide actual  
hardwired ground connections; capacitive coupling to ground  
(Cx1) is always sufficient, even if the coupling might seem  
very tenuous. For example, powering the sensor via an  
isolated transformer will provide ample ground coupling,  
since there is capacitance between the windings and/or the  
transformer core, and from the power wiring itself directly to  
'local earth'. Even when battery powered, just the physical  
size of the PCB and the object into which the electronics is  
embedded will generally be enough to couple a few  
Groundas applied to capacitive fields can also mean power  
wiring or signal lines. The capacitive sensor, being an AC  
device, needs only an AC ground return.  
1.3.5 SENSITIVITY  
ADJUSTMENT  
1.3.5.1 Gain Pin  
The QT118H can be set for one of 3 gain levels using option  
pin 5 (Table 1-1). This sensitivity change is made by altering  
the internal numerical threshold level required for a detection.  
Note that sensitivity is also a function of other things: like the  
values of Cs and Cx, electrode size, shape, and orientation,  
the composition and aspect of the object to be sensed, the  
thickness and composition of any overlaying panel material,  
and the degree of ground coupling of both sensor and object.  
The Gain input should never be connected to a pullup or  
pulldown resistor or tied to anything other than SNS1 or  
SNS2, or left unconnected (for high gain setting).  
picofarads back to local earth.  
1.3.3 VIRTUAL  
C
APACITIVE  
GROUNDS  
When detecting human contact (e.g. a fingertip), grounding  
of the person is never required. The human body naturally  
has several hundred picofarads of free spacecapacitance to  
the local environment (Cx3 in Figure 1-4), which is more than  
two orders of magnitude greater than that required to create  
a return path to the QT118H via earth. The QT118H's PCB  
however can be physically quite small, so there may be little  
free spacecoupling (Cx1 in Figure 1-4) between it and the  
environment to complete the return path. If the QT118H  
circuit ground cannot be earth grounded by wire, for example  
via the supply connections, then a virtual capacitive ground’  
may be required to increase return coupling.  
Figure 1-4 Kirchoff's Current Law  
C
X2  
Sense E lectrode  
A virtual capacitive groundcan be created by connecting the  
QT118Hs own circuit ground to:  
SENSOR  
- A nearby piece of metal or metallized housing;  
- A floating conductive ground plane;  
- Another electronic device (to which its might be  
connected already).  
C
X1  
Free-floating ground planes such as metal foils should  
maximize exposed surface area in a flat plane if possible. A  
square of metal foil will have little effect if it is rolled up or  
C
X3  
Surrounding environm ent  
lq  
3
QT118H R1.08 / 0405  

与QT118H-IG相关器件

型号 品牌 描述 获取价格 数据表
QT118H-IS ETC CHARGE-TRANSFER TOUCH SENSOR

获取价格

QT118H-ISG QUANTUM CHARGE-TRANSFER TOUCH SENSOR

获取价格

QT118H-S ETC CHARGE-TRANSFER TOUCH SENSOR

获取价格

QT12C-SERIES ETC Peripheral IC

获取价格

QT12E-SERIES ETC Peripheral IC

获取价格

QT12HC-SERIES ETC Peripheral IC

获取价格