品牌 Logo 应用领域
高通 - QUALCOMM 传感器
页数 文件大小 规格书
14页 247K
描述
QLEVEL⑩ SENSOR IC

QT114 技术参数

是否Rohs认证: 不符合生命周期:Obsolete
包装说明:SOP, SOP8,.25Reach Compliance Code:unknown
风险等级:5.92Is Samacsys:N
商用集成电路类型:CONSUMER CIRCUITJESD-30 代码:R-PDSO-G8
端子数量:8最高工作温度:70 °C
最低工作温度:封装主体材料:PLASTIC/EPOXY
封装代码:SOP封装等效代码:SOP8,.25
封装形状:RECTANGULAR封装形式:SMALL OUTLINE
电源:3 V认证状态:Not Qualified
子类别:Other Consumer ICs表面贴装:YES
技术:CMOS温度等级:COMMERCIAL
端子形式:GULL WING端子节距:1.27 mm
端子位置:DUALBase Number Matches:1

QT114 数据手册

 浏览型号QT114的Datasheet PDF文件第2页浏览型号QT114的Datasheet PDF文件第3页浏览型号QT114的Datasheet PDF文件第4页浏览型号QT114的Datasheet PDF文件第6页浏览型号QT114的Datasheet PDF文件第7页浏览型号QT114的Datasheet PDF文件第8页 
T1  
Figure 2-9 Twin-Level Internal Horizontal Probes  
Figure 2-8 Single Internal Horizontal Probe  
T2  
Figure 2-10 Coaxial Probe For Non-Aqueous Fluids  
Figure 2-11 Twin-Level Coaxial Probes For  
Non-Aqueous Fluids  
A bare internal probe used with conductive fluids and an  
in-line blocking capacitor will generate a huge, robust  
capacitive response that will not readily permit the use of a  
two-level probe due to signal saturation. Even the slightest  
amount of bare metal exposed to the fluid will usually  
generate an immediate, large response with aqueous fluids.  
2.2.7 VISCOUS, CONDUCTIVE  
F
ILMS  
Highly viscous fluids, or those having a high surface tension,  
and having substantial conductivity can fool some electrode  
designs into thinking that there is fluid present when there is  
not. This is a particular problem with external electrodes,  
where the residual films of certain types of fluids inside the  
container, electrically coupled to the fluid mass below, will  
create a substantial capacitive response. Internal probes are  
much more resistant to this effect since the fluid surface is  
guaranteed to become mechanically disconnected from the  
probe when the level drops. Coating the inner vessel surface  
with a smooth plastic of polyethylene or PTFE often has a  
very beneficial effect on this phenomenon.  
2.2.6 SCALE  
B
UILDUP  
Scale buildup on internal probes, bare or insulated, is not  
generally a problem since the sensor is still measuring  
capacitance, not conductance, and  
a
reduction in  
conductivity around the probe will have minimal or no effect.  
Probe designs should be tested for this to be certain in all  
specific cases.  
2.3 SINGLE LEVEL SENSING  
A legitimate concern with bare metal probes is the buildup of  
scale or other deposits at the entry point of the probe into the  
vessel. Such deposits may create a conductive surface path  
(especially if the vessel is made of metal) that may lead to  
false-positive trips. If the shank of the probe at the entry point  
is insulated enough so that conductive bridging cannot occur,  
this problem should be alleviated.  
When sensing for a single trip point, the single electrode can  
be a simple horizontal strip on the outside of a nonmetallic  
vessel (Figure 2-2), or an internal probe having a substantial  
horizontal 'plateau' at the trip point (Figures 2-4, 2-5, 2-8,  
2-10). When the strip or plateau is ‘covered’ with fluid the IC  
will detect on at least the OUT1 line; OUT2 can be ignored.  
LQ  
5
QT114 R1.04/1106  

与QT114相关器件

型号 品牌 描述 获取价格 数据表
QT114_06 QUALCOMM QLEVEL⑩ SENSOR IC

获取价格

QT114-D QUANTUM CHARGE-TRANSFER QLEVEL SENSOR IC

获取价格

QT114-DG QUALCOMM QLEVEL⑩ SENSOR IC

获取价格

QT114-IS QUANTUM CHARGE-TRANSFER QLEVEL SENSOR IC

获取价格

QT114-ISG QUALCOMM QLEVEL⑩ SENSOR IC

获取价格

QT114-S QUANTUM CHARGE-TRANSFER QLEVEL SENSOR IC

获取价格