150W Quad Output with PFC Function
QP-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Over load / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-150-3A
QP-150-3B
QP-150-3C
OUTPUT NUMBER
CH1
5V
CH2
3.3V
10A
CH3
12V
5A
CH4
-5V
CH1
5V
CH2
CH3
12V
5A
CH4
-12V
0.6A
CH1
5V
CH2
CH3
15V
4A
CH4
-15V
0.6A
DC VOLTAGE
3.3V
10A
3.3V
10A
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
10A
0.6A
10A
10A
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
146W
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
150.2W
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
152W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
OUTPUT
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
+8,-6%
2.0%
5.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
6.0%
800ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
24ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
PF>0.95/230VAC
73%
PF>0.98/115VAC at full load
75%
74%
INPUT
2.5A/115VAC
1.2A/230VAC
COLD START 40A/230V
<3.5mA / 240VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1)
PROTECTION
OVER VOLTAGE
5
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
)
DIMENSION
PACKING
OTHERS
NOTE
0.93Kg; 20pcs/19.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2010-10-18