100W Quad Output with PFC Function
QP-100 series
■ Features :
$Universal AC input / Full range
$Built-in active PFC function, PF>0.95
$Protections: Short circuit / Overload / Over voltage
$Free air cooling convection
$CH4: Polarity is selectable
$Fixed switching frequency at 100KHz
$3 years warranty
..
SPECIFICATION
MODEL
QP-100-3A
QP-100-3B
QP-100-3C
OUTPUT NUMBER
CH1
5V
CH2
CH3
12V
2.5A
CH4
-5V
CH1
5V
CH2
CH3
12V
2.2A
CH4
-12V
0.6A
CH1
5V
CH2
CH3
15V
1.7A
CH4
-15V
0.6A
DC VOLTAGE
3.3V
8A
3.3V
8A
3.3V
8A
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
8A
0.6A
8A
8A
2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A
99.4W
2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A
100W
2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A
100.9W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
OUTPUT
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
+8,-6%
2.0%
5.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
2.0%
6.0%
800ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
24ms/230VAC
Note.5 90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.95/230VAC
74%
PF>0.98/115VAC at full load
74%
75%
INPUT
1.5A/115VAC
0.75A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START ≦40A/230V
<3.5mA / 240VAC
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
95℃ 5℃ (TSW1)
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60℃ (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0~50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
139.9K hrs min. MIL-HDBK-217F (25℃)
199*99*50mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
0.87Kg; 20pcs/18.4Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-100-SPEC 2007-10-25