QM48T/S14120 DC-DC Converter Data Sheet
36-75 VDC Input; 12 VDC @ 14 A Output
Electrical Specifications (Common for both Non-paralleling and Paralleling Options)
Conditions: TA = 25 ºC, Airflow = 300 LFM (1.5 m/s), Vi n = 48 VDC, unless otherwise specified.
Parameter
Notes
Min
Typ
Max Units
Absolute Maximum Ratings
Input Voltage
Continuous
0
80
85
VDC
°C
Operating Ambient Temperature
Storage Temperature
Isolation Characteristics
I/O Isolation
-40
-55
125
°C
2000
10
VDC
ηF
Isolation Capacitance
Isolation Resistance
1.2
MΩ
Feature Characteristics
Switching Frequency
300
kHz
%
Output Voltage Trim Range1
Industry-standard equations
Percent of VOUT(NOM)
Non-latching
-20
+10
+10
135
Remote Sense Compensation1
Output Overvoltage Protection
Overtemperature Shutdown (PCB)
Auto-Restart Period
%
115
128
125
100
4
%
Non-latching
°C
ms
ms
Applies to all protection features
Turn-On Time
ON/OFF Control (Positive Logic)
Converter Off (logic low)
Converter On (logic high)
ON/OFF Control (Negative Logic)
Converter Off (logic high)
Converter On (logic low)
Input Characteristics
-20
2.4
0.8
20
VDC
VDC
2.4
-20
20
VDC
VDC
0.8
Operating Input Voltage Range
Input Under Voltage Lockout
Turn-on Threshold
36
48
75
VDC
Non-latching
33
31
34
32
35
33
VDC
VDC
Turn-off Threshold
Input Voltage Transient
100 ms
100
VDC
Input Stand-by Current
Vin = 48 V, converter disabled
Vin = 48 V, converter enabled
25 MHz bandwidth
3
mADC
mADC
mAPK-PK
Input No Load Current (0 load on the output)
Input Reflected-Ripple Current
65
20
Additional Notes:
1
Vout can be increased up to 10% via the sense leads or up to 10% via the trim function (Vin > 40 V). However, the total output voltage trim
from all sources should not exceed 10% of VOUT(NOM), in order to ensure specified operation of overvoltage protection circuitry.
ZD-00376 Rev. 1.1.1, 19-Feb-10
Page 2 of 20