P
ualtek
Q
P C
150Watts Single Output
QGKF-150 Series
Electronics Corporation
Features:
Universal AC input/ Full range
Built-in active PFC function, PF>0.95
Miniature Size, High Efficiency, and High Reliability
Output Protections: OLP/OVP/OPP/OTP/SCP
Withstand 300VAC Surge Input for 5 Sec
Suitable for critical applications
Wide operating ambient temperature (-20°C~70°C)
PCB soldering side with conformal coating
All using 105°C long life electrolytic capacitors.
100% full load burn-in test
CB
QGKF-150-48
QGKF-150-12
QGKF-150-15
QGKF-150-24
Model
Output Characteristics
DC Output
12V
15V
24V
48V
12.5A
10.0A
6.3A
3.2A
Rated Current
0~12.5A
≤100mV
≤200mV
10.8V~13.2V
2.0%
0~10.0A
≤100mV
≤200mV
13.5V~16.5V
2.0%
0~6.3A
≤100mV
≤200mV
21.6V~26.4V
2.0%
0~3.2A
≤100mV
≤200mV
43.2V~52.8V
2.0%
Current Range (Note 1)
Ripple and
0~70°C
Noise (Note 2)
-20~0°C
Voltage ADJ. Range
Voltage Accuracy
Line Regulation
Load Regulation
Set-up Time
0.5%
2.0%
0.5%
2.0%
0.5%
1.0%
0.5%
1.0%
≤3.0s (115VAC input, full load) ≤2.0s (230VAC input, full load)
≥10ms (230VAC input, full load)
Hold-up Time
0.03%/°C
<5.0%
Temperature Coefficient
Overshoot and Undershoot
Input Characteristics
Voltage Range
90VAC~264VAC
Frequency Range
47Hz-63Hz
Power Factor (Typical)
PF>0.98/115VAC PF>0.95/230VAC
Efficiency (Typical) 230VAC Input 86%
87%
87%
88%
AC Current (max)
Inrush Current (Typical)
Leakage Current
<2.0A
<30A@115VAC Cold start <45A@230VAC Cold start
Input-Output: <0.25mA Input-PG: <3.5mA
Protection
Over Load (OLP)
105%~150% of rated output current, hiccup mode, auto recovery
105%~150% of rated output power, hiccup mode, auto recovery
115%~150% of rated output voltage, hiccup mode, auto recovery
105°C 5°C(detect from Mosfet temp)ꢀ shutdown, auto recovery after the temperature decreases to 60°C
Long-term mode, auto recovery
Over Power (OPP)
Over Voltage (OVP)
Over Temperature (OTP)
Short Circuit (SCP)
Environmental Characteristics
Operating Amb. Temp. & Hum
Storage Temp. & Hum
Safety Standards
-20°C~70°Cꢀ 20%~90% RH Non-Condensing
-30°C~85°C: 10%-95% RH Non-Condensing
UL60950-1 2nd Edꢀ IEC 60950-1:2005(2nd Ed)ꢀ EN60950-1: 2006
Primary-Secondary: 3.0KVACꢀ≤10mA. Primary-PG: 1.5KVACꢀ≤10mA. Secondary-PG: 0.5KVDCꢀ≤10mA
100M ohms
Withstand Voltage
Isolation Resistance
EMI Conduction & Radiation
Harmonic Current
Compliance to EN55022 Class B
Compliance to EN61000-3-2, Class A
EMS Immunity
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11ꢀ heavy industry level
General Characteristics
MTBF (MIL-HDBK-217F)
More than 200,000Hrs (25°C, Full load)
Dimension (LxWxH)
Packing
Cooling Method
Note
160x98.3x38mm
20PCS/CTN. G.W: 14kgs
Cooling by free air convection
1. All parameters NOT specially mentioned are measured at rated input, rated load, and 25°C of ambient temperature
2. Measured at 20MHz of bandwith by using a 12” Twisted pair wire terminated with a 0.1uF & 47uF parallel capacitor
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
Page 1 of 2