Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 3: Normalized DC Holding Current
vs. JunctionTemperature
Figure 4: Normalized DC GateTriggerVoltage for
All Quadrants vs. JunctionTemperature
2.0
1.5
1.0
0.5
0.0
4.0
3.0
2.0
1.0
0.0
-65
-40
-40
10
35
60
85
110
125
-65
-40
-15
10
35
60
85
110
125
JunctionTemperature (T )- °C
Junction Temperature (TJ)- ºC
J
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable CaseTemperature
vs. On-State Current (SensitiveTriac)
120
110
18
16
14
12
10
8
Lxx06Ry
100
90
80
70
60
Lxx06Ly
Lxx06Vy
Lxx06Dy
6
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
4
2
0
CONDUCTION ANGLE: 360°
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
0
2
4
6
8
10
12
14
16
0
1
2
3
4
5
6
7
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable CaseTemperature
vs. On-State Current (StandardTriac)
Figure 8: Maximum Allowable CaseTemperature
vs. On-State Current (AlternistorTriac)
130
130
120
120
Qxx06RHy
Qxx06NHy
Qxx06Ry
Qxx06Ny
110
110
100
100
Qxx06LHy
Qxx06VHy
Qxx06Ly
90
90
Qxx06DHy
80
80
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CONDUCTION ANGLE: 360°
70
60
70
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
60
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.