R-GAGE Q120RA-AF2W Sensor
1. Output LEDs: Yellow (output 1 energized); Red
(configuration)
2. Output LEDs: Yellow (output 2 energized); Red
(configuration)
3. Power LED: Green (power ON)
4. Signal Strength LED: Red (flashes in proportion to
the signal strength)
5. DIP switch row A
6. DIP switch row B
3
4
1
2
Access the DIP switches behind the threaded cap on the
sensor side
5
6
Figure 1. R-GAGE features
Zone 1
X
Zone 2
Y
A
B
D
Figure 2. R-GAGE setpoint distances
EU, KR Models
US Models
3.5 m (11.5 ft)
12 m (39.4 ft)
5 m (16.4 ft)
26 m (85.3 ft)
X
Y
Minimum Zone 1 setpoint distance
Maximum Zone 1 setpoint distance
2 m (6.6 ft)
12 m (39.4 ft)
4 m (13.1 ft)
26 m (85.3 ft)
A
B
D
Minimum Zone 2 (offset from Zone 1: 2 m to 14 m)
Maximum Zone 2 (offset from Zone 1: 2 m to 14 m)
2
Dead Zone
Sensor Configuration
The sensitivity and output configuration can be selected via the DIP switches on the side of the sensor. Use the included
spanner to open the screw-off cover on the side of the sensor and access the DIP switches.
Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight
seal.
DIP Switch Functions
Switches
Function
A1, A2, A3, A4
A5, A6, A7
Zone 1 Distance (detects objects from sensor face to this point)
Zone 2 Distance, Offset from Zone 1
2
Typical dead zone: 0.4 m (1.3 ft) for moving and 1.0 m (3.3 ft) for stationary targets, but varies with target reflectivity.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 189332 Rev. C