R-GAGE Q120RA-AF Sensor  
Dimensions  
All measurements are listed in millimeters, unless noted otherwise.  
50.75  
4X  
5
Mounting holes  
Indicator LEDs  
159.5  
140.79  
Cover for DIP switch  
M12/Euro-style QD  
6.5  
90.8  
62  
Windows  
The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the  
distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20%  
signal reduction when the sensor is placed behind a window.  
Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials.  
Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and  
distance from the sensor to the window.  
Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance  
between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums,  
and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window  
materials which can be used at any distance without issue.  
Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood  
directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the  
face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of  
the window can be detected as a dielectric boundary.  
Wiring  
Wiring Key:  
1
+
12-30V dc  
1 = Brown  
3
2
4
2 = White  
Load 1  
Load 2  
3 = Blue  
5
4 = Black  
shield (QD cordset)  
5 = Gray (Do not connect)  
NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc  
common. Shielded cordsets are recommended for all QD models.  
6
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 169605 Rev. E  

与Q120RA-AF相关器件

型号 品牌 描述 获取价格 数据表
Q120RA-AF2 BANNER R-GAGE® Q120RA-AF2 Sensor

获取价格

Q120RA-AF2W BANNER R-GAGE® Q120RA-AF2W Sensor

获取价格

Q120RA-EU-AF BANNER R-GAGE® Q120RA-AF Sensor

获取价格

Q120RA-EU-AF2 BANNER R-GAGE® Q120RA-AF2 Sensor

获取价格

Q120RA-EU-AF2W BANNER R-GAGE® Q120RA-AF2W Sensor

获取价格

Q120RA-KR-AF BANNER R-GAGE® Q120RA-AF Sensor

获取价格