Medical Grade 150 Watt with DIN Rail mount and PFC
Pmmk150-D series
INPUT SPECIFICATIONS
ENVIRONmENTAL SPECIFICATIONS
Input Voltage Range
Frequency Range
90-264 VAC
47-63 Hz
Oper. Temperature
-10 to +70°C
(See Derate Curve)
-25 to +85°C *
0% to +95%, non-cond *
EN55011 Class B
270,000 Hrs
Power Factor Correction
Inrush Current, typ:
0.96 to 0.98
Storage Temperature
Relative Humidity
EMC
30A @ 115VAC
60A @ 230VAC *
MTBF
Mil Std 217, 25°C
OUTPUT SPECIFICATIONS
Voltage and Current (Note 6)
Line Regulation (Note 8)
Load Regulation (10%-FL, Note 7)
Singles:
See Selection Chart
See Selection Chart
PHYSICAL SPECIFICATIONS
Size
3.2” x 5.5” x 1.6”
Enclosed DIN Rail
1.4 lb, (635g)
± 0.5%, typ
Construction
Weight
Duals:
±3/5%, typ
Preset Accuracy (Note 9)
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise (Notes 1, 3, 10)
Over Voltage Protection
±1%, typ
±6%, typ
NOTES
±0.05%/°C
See Selection Chart
Latching, Auto Recover after fault
condition is removed *
Latching, Auto Recover after fault
condition is removed *
20mS, typ (Nom I/P, FL)
1. All measurements should be made directly at the terminals of the
power supply
2. All specifications typical @ 25°C, unless otherwise noted, at
nominal line and load.
3. Ripple and noise dependent upon output voltage as specified per
particular model.
Short Circuit Protection
Hold Up Time
4. Isolation for up to 1 minute duration.
5. Specified for free air convection cooling.
GENERAL SPECIFICATIONS
6. Minimum load is not required for proper operation.
7. Load Regulation is measured by change ±40% of measured
output load from 60% full load, with the other output set to 60% full
load.
8. Line Regulation measured from 90-264VAC. 100VAC minimum
required for full load start.
Isolation (Note 4)
I/P-O/P: 4000VAC
I/P-Ground: 2000VAC
O/P-Ground: 500 VAC
75%, min.
Efficiency
Switching Frequency
Safety
67Khz, (fixed, typical)
UL,TUV, CB, CE
9. Preset Accuracy measured at nominal load, 120VAC input.
10. O/P Noise measured directly at the pins/terminals at nominal load,
0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.