Industrial Line – PMC02W Series
2W 4:1 SINGLE & DUAL OUTPUT DC/DC CONVERTER
Specifications
INPUT
Voltage range
12V nominal input
24V nominal input
48V nominal input
Capacitor type.
12V
4.5-18VDC
9-36VDC
18-75VDC
Input filter
Input surge voltage
100mS max
25VDC 1 sec max
50VDC 1 sec max
100VDC 1 sec max
80mA p-p
24V
48V
Reflected ripple current6 12V
24V
48V
Power up
Remote ON/OFF
Nominal Vin and constant resistive load.
DC/DC ON: Open or high impedance.
DC/DC OFF: Control pin applied current.
2-4mA max (via 1KW).
40mA p-p
30mA p-p
5mS
5mS
Features
•ꢀ SMDꢀandꢀDIPꢀpackage
Start up time
•ꢀ SMDꢀpackageꢀqualifiedꢀforꢀleadfreeꢀreflowꢀsolderꢀ
ꢀ processꢀaccordingꢀtoꢀJ-STD-020D
Remote ON/OFF
•ꢀ 4:1ꢀwideꢀinputꢀvoltageꢀrange
Remote off state current Nominal input
Application circuit
2.5mA max.
•ꢀ Highꢀefficiencyꢀupꢀtoꢀ82%
•ꢀ Inputꢀtoꢀoutputꢀisolationꢀ1600VDC
•ꢀ Lowꢀrippleꢀandꢀnoise
•ꢀ Externalꢀon/offꢀcontrol
•ꢀ Switchingꢀfrequencyꢀ(100KHz,ꢀmin)
•ꢀ Continuousꢀshortꢀcircuitꢀprotection
•ꢀ UL94-V0ꢀpackageꢀmaterials
OUTPUT
Power
Voltage accuracy
Min load
Line regulation
Load regulation
2W max.
1ꢀ.
0ꢀ.
0.2ꢀ, LL to HL at full load.
Single 1.0ꢀ.
Dual 1.0ꢀ
•ꢀ CEꢀmarkꢀmeetsꢀ2006/EC,ꢀ93/68/EECꢀandꢀ2004/108/EC
•ꢀUL60950-1,ꢀEN60950-1ꢀandꢀIEC60950-1ꢀlicenced
•ꢀCompliantꢀtoꢀRoHSꢀEUꢀDirectiveꢀ2002/95/EC
No load to full load.
Single 0.5ꢀ.
Dual 0.8ꢀ
10ꢀ load to 90ꢀ load.
5ꢀ, asymmetrical load 25ꢀ / 100ꢀ FL.
See table, 20MHz BW.
GENERAL
Efficiency
Isolation voltage
See table.
Standard
1600VDC, min 1 minute.
3000VDC, min 1 minute.
Suffix “H”
109 ohms, min.
Standard
Suffix “H”
100KHz min.
18.9 x 12.8 x 8.4 mm.
4.5g.
BELLCORE TR-NWT-000332 4.615 x 106 hrs.
MIL-HDBK-217F 2.052 x 105.
Cross regulation (dual)
Ripple and noise
Isolation resistance
Isolation capacitance
50pF, max.
50pF, max.
Temperature coefficient 0.02ꢀ/ꢁC max.
250mS,recovery time 25ꢀ load step change.
Short circuit protection Continuous, automatics recovery.
Transient response
Switching frequency
Dimensions
Weight
ENVIRONMENTAL
MTBF1
Operating ambient temp.–40ꢁC to +85ꢁC (non-derating).
Storage temperature
Thermal shock
Vibration
–55ꢁC to +125ꢁC.
MIL-STD-810F.
MIL-STD-810F.
STANDARDS
Safety standards
EMC EMI6
IEC60950-1, UL60950-1, EN60950-1.
EN55022 Class A.
Relative humidity
5-95ꢀ RH (non-condensing).
Lead-free reflow solder process IPC J-STD-020D.
Moisture sensitivity level IPC J-STD-033B, Level 2A.
ESD
EN61000-4-2 Criteria A, air 8KV, contact 6KV.
EN61000-4-3 Criteria A, 10V/m.
EN61000-4-4 Criteria A, 2KV.
EN61000-4-5 Criteria A, 1KV.
EN61000-4-6 Criteria A, 10 Vr.m.s.
Radiated immunity
Fast transient7
Surge7
Conducted immunity
20120611
I N D U S T R I A L L I N E
w w w . p o w e r b o x . i n f o