5秒后页面跳转
PM100RSE060_05 PDF预览

PM100RSE060_05

更新时间: 2022-12-23 11:16:41
品牌 Logo 应用领域
三菱 - MITSUBISHI /
页数 文件大小 规格书
9页 145K
描述
INTELLIGENT POWER MODULES FLAT-BASE TYPE INSULATED PACKAGE

PM100RSE060_05 数据手册

 浏览型号PM100RSE060_05的Datasheet PDF文件第3页浏览型号PM100RSE060_05的Datasheet PDF文件第4页浏览型号PM100RSE060_05的Datasheet PDF文件第5页浏览型号PM100RSE060_05的Datasheet PDF文件第7页浏览型号PM100RSE060_05的Datasheet PDF文件第8页浏览型号PM100RSE060_05的Datasheet PDF文件第9页 
MITSUBISHI <INTELLIGENT POWER MODULES>  
PM100RSE060  
FLAT-BASE TYPE  
INSULATED PACKAGE  
P
10µ  
20k  
VUP1  
Vcc  
In  
OUT  
Si  
+
VD  
IF  
UP  
U
VUPC  
GND GND  
0.1µ  
VVP1  
Vcc  
OUT  
Si  
V
D
D
VP  
In  
V
VVPC  
GND GND  
M
VWP1  
Vcc  
OUT  
Si  
V
WP  
In  
W
VWPC  
GND GND  
20k  
Vcc  
Fo  
In  
OUT  
Si  
10µ  
IF  
UN  
GND GND  
0.1µ  
N
Th  
20k  
TEMP  
Vcc  
OUT  
10µ  
10µ  
Fo  
IF  
Si  
VN  
In  
GND GND  
0.1µ  
20k  
VN1  
WN  
Vcc  
OUT  
Fo  
IF  
VD  
Si  
In  
GND GND  
B
0.1µ  
VNC  
4.7k  
Vcc  
OUT  
Fo  
Br  
Si  
In  
GND GND  
1k  
5V  
Rfo  
Fo  
: Interface which is the same as the U-phase  
Fig. 8 Application Example Circuit  
NOTES FOR STABLE AND SAFE OPERATION ;  
Design the PCB pattern to minimize wiring length between opto-coupler and IPMs input terminal, and also to minimize the  
stray capacity between the input and output wirings of opto-coupler.  
Quick opto-couplers: TPLH, TPLH 0.8µs. Use High CMR type. The line between opto-coupler and intelligent module  
should be shortened as much as possible to minimize the floating capacitance.  
Slow switching opto-coupler: recommend to use at CTR = 100 ~ 200%, Input current = 8 ~ 10mA, to work in active.  
Use 4 isolated control power supplies (VD). Also, care should be taken to minimize the instantaneous voltage charge of the  
power supply.  
Make inductance of DC bus line as small as possible, and minimize surge voltage using snubber capacitor between P and N  
terminal.  
Use line noise filter capacitor (ex. 4.7nF) between each input AC line and ground to reject common-mode noise from AC line  
and improve noise immunity of the system.  
Jul. 2005  

与PM100RSE060_05相关器件

型号 品牌 描述 获取价格 数据表
PM100RSE060_09 MITSUBISHI FLAT-BASE TYPE INSULATED PACKAGE

获取价格

PM100RSE120 MITSUBISHI FLAT-BASE TYPE INSULATED PACKAGE

获取价格

PM100RSE120_07 MITSUBISHI FLAT-BASE TYPE INSULATED PACKAGE

获取价格

PM100RSE120_09 MITSUBISHI FLAT-BASE TYPE INSULATED PACKAGE

获取价格

PM100-S EXTECH Medidor de potencia de fibra ®tica con foto d

获取价格

PM100WX6 AZDISPLAYS TECHNICAL SPECIFICATION

获取价格