P-511-508(V:4)
PD057VU7
15. Reliability Test
No
Test Item
Test Condition
Ta = +85к, 240 hrs
Remark
1 High Temperature Storage Test
Ta = -40к, 240 hrs
2 Low Temperature Storage Test
3 High Temperature Operation Test
4 Low Temperature Operation Test
Ta = +80к, 240 hrs
Ta = -30к, 240 hrs
Ta = +60к, 90%RH, 240 hrs
High Temperature & High Humidity
5
Operation Test
(No Condensation)
-20кꢀ+70к, 200 Cycles
Thermal Cycling Test
6
(non-operating)
30 min
30 min
Frequency: 10 ~ 57 HZ /Vibration
Width:0.075 mm
Vibration Test
(non-operating)
58-500 Hz / Gravity: 9.8m/s2
Sweep time: 11 minutes
7
Test period: 3 hrs for each direction of X, Y, Z
Gravity: 490m/s2 * 6ms
Shock Test
(non-operating)
Direction: ̈́X, ̈́Y, ̈́Z
3 times for each direction
8
Machine Mode =
C = 200pF , R = 0
̈́200V
Electrostatic Discharge Test
(non-operating)
Ө
9
1 times discharge for each pad
1,000,000 times, with R 8.0 mm silicon rubber,
250g, 3times/sec
Hitting Durability Test
(Touch panel)
10
Sliding Durability Test
(Touch panel)
1,00,000 times, with R 0.8 mm polyacetal stylus,
250g, 60mm/sec
11
Ta: ambient temperature
Note: The protective film must be removed before temperature test
[Criteria]
In the standard conditions, there is not display function NG issue occurred.
(IncludingΚline defect, no image) All the cosmetic specification is judged before
the reliability stress.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:19