AC Output Solid State Relay
PCS27 AC Output
FEATURES
2 A or 3 A Output
DC Input: 5 VDC; 12 VAC; 24 VAC
PCB Mount
Built in Snubber
Photoelectric Isolation
RoHS Compliant
E93397
INPUT PARAMETERS (Ta = 25°C)
OUTPUT PARAMETERS (Ta = 25°C)
5
4 - 6 VDC
9.6 - 14.4 VDC
19.2 - 28.8 VDC
4 VAC
Amperage, Voltage
2,240
48-280 48-440 48-280 48-440
VAC VAC VAC VAC
600 Vpk 800 Vpk 600 Vpk 800 Vpk
2, 380
2,240
3,380
Control Voltage Range
12
24
5
Load Voltage Range
Max. Transient Voltage
Load Current Range
Must Turn-On Voltage
Max. Input Current
12
24
9.6 VAC
0.1 - 2 A
60 Apk
18
0.1 - 3 A
80 Apk
32
19.2 VAC
25 mA
Max. Surge Current (10 ms)
Max. I2t (10 ms, A2s)
5
250 Ω
Max. On-State Voltage Drop
Max. Off-State Leakage Current
1.5 VRMS
5 mA
Input Resistance
12
24
720 Ω
1.64 kΩ
Min. Off-State dv/dt
Max. Turn-On Time
200 V/us
Must Turn-Off Voltage
1 VDC
Zero Cross: 1/2 Cycles + 1 ms;
Random: 1 ms
Max. Turn-Off Time
Frequency Range
Min. Power Factor
1/2 Cycles + 1 ms
47 - 63 Hz
0.5
CHARACTERISTICS
Dielectric Strength
4,000 VAC, 50 Hz/60 Hz, 1 min. (Input to Output)
1,000 MΩ at 500 VDC (Input to Output)
8 pF (Input to Output)
Operating Temperture
Storage Temperature
Relative Humidity
- 30°C to 80°C
- 30°C to 100°C
45% - 85%
Insulation Resistance
Max. Capacitance
Shock Resistance
Acceleration 980 m/s2, Continuous Surge 6 ms
10 Hz - 55 Hz 1.5 mmm DA
Weight
Approximately 70 g
Vibration Resistance
ORDERING INFORMATION
Example:
PCS27
‐12D ‐240A
‐2
Z
Model: PCS27 AC Output
Control Voltage: 5D: 4‐6 VDC
12D: 9.6 ‐ 14.4 VDC,
24D: 19.2 ‐ 28.8 VDC
Load Voltage: 240A: 240VAC, 380A: 380 VAC
Load Current: 2: 2 Amp, 3: 3 Amp
Switching Type: Z: Zero Crossing, R: Random Turn‐On
Box Quantity: 540; Inner Box 27
3220 Commander Drive, Suite 102 Carrollton, TX 75006
www.PickerComponents.com
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
e-mail: sales@pickercomponents.com
Dimensions are listed for reference purposes only.
PCS27 AC Output Rev A 8/4/15
Specifications and Availability subject to change without notice.
1 of 2