LOW PROFILE SELF-LEADED
SMT DUAL INDUCTORS
Materials meet UL 94V-0 rating
Frequency range of up to 1 MHz
Can be used as a simple inductor, 1:1
coupled inductor, or 1:1 transformer
Electrical Specifications @ 25°C — Operating Temperature -40°C to +130°C
ID
Reference Values
Control Values
Calculation Data
L @ DC
L W/O DC
100 Gauss
1 Amp DC
Part
Number
IDC
(A)
ET
(V-µsec)
DCR (MAX)
Hookup
LDC
L0 20ꢀ
ET100
H1
(mΩ)
(µH)
(µH)
(V-µsec)
(Orsted)
P0183
P0182
P0181
P0180
P0183
P0179
P0182
P0178
P0181
P0177
P0180
P0176
P0179
P0178
P0175
P0177
P0174
P0176
P0175
P0174
Series
Series
Series
Series
Parallel
Series
Parallel
Series
Parallel
Series
Parallel
Series
Parallel
Parallel
Series
Parallel
Series
Parallel
Parallel
Parallel
0.61
0.74
0.90
1.08
1.22
1.32
1.48
1.56
1.80
1.92
2.16
2.60
2.64
3.12
3.60
3.84
4.15
5.20
7.20
8.30
336.7
245.3
170.3
117.3
84.2
79.0
61.3
56.2
42.6
37.3
29.3
20.0
19.7
14.1
9.6
92.43
81.70
68.99
57.00
46.22
46.90
40.85
39.46
34.49
32.25
28.50
23.43
23.45
19.73
15.62
16.12
14.61
11.72
7.81
364.0
270.2
190.3
131.0
91.0
88.2
67.5
62.8
47.6
41.7
32.8
22.1
22.1
15.7
10.4
10.4
8.6
1295
897
603
424
324
265
224
181
151
119
106
76.0
66.3
45.3
43.6
29.8
30.3
19.0
10.9
7.6
15.66
13.50
11.33
9.40
7.83
7.71
6.75
6.51
5.66
5.30
4.70
3.86
3.86
3.25
2.65
2.65
2.41
1.93
1.33
1.20
70.59
60.82
51.05
42.36
35.30
34.75
30.41
29.32
25.52
23.89
21.18
17.38
17.38
14.66
11.95
11.95
10.86
8.69
9.3
7.8
5.0
2.4
5.5
2.6
2.2
5.97
5.43
2.0
7.31
NOTES:
1. The reference inductance at rated DC current is a typical value.
2. Temperature rise is 50°C in typical buck or boost circuits at 250 KHz and with the
reference ET applied to the inductor.
6. For core loss, using frequency (f) and operating flux density (B),
calculate 6.11 x 10-18 x B2.7 x f2.04
7. For flux density (B), calculate ET (V-µsec) for the application, divide by ET100 from
the table, and multiply by 100.
.
3. Total loss in the inductor is 380 mWatts for a 50°C temperature rise above ambient.
4. To estimate temperature rise in a given application, determine copper and core
losses, divide by 380 and multiply by 50.
8. Limit the DC bias (H) to 46 orsteds. Calculate H by multiplying H1 from the table by
IDC of the application.
9. The maximum DCR listed is approximately 17ꢀ over the nominal DCR.
10. Add suffix "T" to part number for tape and reel package (i.e. P0183T).
5. For the copper loss, calculate IDC 2X RN.
Schematic
Mechanical
.500
12,70
.330
8,38
MAX
4
3
1
2
R
2
1
.060
1,52
4X
1:1 1ꢀ
.500
12,70
.410
10,41
MAX
P01XX
Date Code
.175
4,45
Country of Origin
4X
Weight . . . . . . . . 1.5 grams
Tape & Reel. . . . . . 500/reel
Tube . . . . . . . . . . . . 40/tube
3
4
Suggested Pad Layout
Inches
mm
Dimensions:
.215
5,46
Unless otherwise specified,
MAX
.010
0,25
all tolerances are
.005/0,13
4 SURFACES
.410
10,41
.330
8,38
•
•
•
•
•
•
US 858 674 8100 UK 44 1483 401 700 France 33 3 84 35 04 04 Singapore 65 287 8998 Taiwan 886 2 2698 0228 Hong Kong 852 2788 6588 http://www.pulseeng.com
24