P01 Series
®
SENSITIVE
0.8A SCRs
MAIN FEATURES:
Symbol
A
Value
0.8
Unit
A
G
I
T(RMS)
K
V
/V
400 and 600
5 to 200
V
DRM RRM
I
µA
GT
DESCRIPTION
Thanks to highly sensitive triggering levels, the
P01 SCR series is suitable for all applications
where available gate current is limited, such as
ground fault circuit interruptors, pilot circuits in
solid state relays, stand-by mode power supplies,
smoke and alarm detectors.
SOT-223
(P01xxN)
TO-92
(P01xxA)
Available in through-hole or surface mount pack-
ages, the voltage capability of this series has been
upgrated since its introduction, to reach 600 V.
ABSOLUTE RATINGS (limiting values)
Symbol
Parameter
Value
Unit
I
RMS on-state current
(180° conduction angle)
TO-92
SOT-223
TO-92
Tl = 55°C
Tamb = 70°C
Tl = 55°C
T(RMS)
0.8
0.5
A
IT
Average on-state current
(180° conduction angle)
(AV)
A
A
SOT-223
tp = 8.3 ms
tp = 10 ms
Tamb = 70°C
I
Non repetitive surge peak on-state
current
8
7
TSM
Tj = 25°C
²
²
2
tp = 10ms
F = 60 Hz
tp = 20 µs
Tj = 25°C
0.24
50
A S
I t
I t Value for fusing
Critical rate of rise of on-state current
dI/dt
Tj = 125°C
A/µs
I
= 2 x I , tr ≤ 100 ns
G
GT
I
Peak gate current
Tj = 125°C
Tj = 125°C
1
A
GM
P
Average gate power dissipation
0.1
W
G(AV)
T
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
stg
°C
Tj
September 2000 - Ed: 3
1/6