OPA387, OPA2387, OPA4387
ZHCSMQ4F –NOVEMBER 2020 –REVISED FEBRUARY 2022
www.ti.com.cn
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
MIN
MAX
UNIT
Single-supply
6
±3
VS
V
Supply voltage, VS = (V+) –(V–)
Dual-supply
Common-mode
Differential
(V+) + 0.5
(V–) –0.5
Input voltage, all pins
V
(V+) –(V–) + 0.2
Input current, all pins
Output short circuit(2)
Operating temperature
Junction temperature
Storage temperature
±10
Continuous
150
mA
Continuous
–55
TA
°C
°C
°C
TJ
150
–55
Tstg
150
–65
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply
functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If
used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully
functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
VALUE
±3000
±1000
UNIT
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per ANSI/ESDA/JEDEC JS-002(2)
V(ESD)
Electrostatic discharge
V
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
1.7
NOM
MAX
5.5
UNIT
V
Single-supply
Dual-supply
VS
TA
Supply voltage, VS = (V+) –(V–)
±0.85
–40
±2.75
125
Specified temperature
°C
Copyright © 2022 Texas Instruments Incorporated
Submit Document Feedback
7
Product Folder Links: OPA387 OPA2387 OPA4387