Isolated 10W Single Output DC/DC Converters

NPH10S4803EI 数据手册

 浏览型号NPH10S4803EI的Datasheet PDF文件第2页 
NPH10S SERIES  
Isolated 10W Single Output DC-DC Converters  
SELECTION GUIDE  
Nominal  
Input Voltage  
Output  
Voltage  
Output  
Current  
Current  
Max Load  
2
Limit (Typ) Efficiency Capacitance  
1
Order Code  
(V)  
24  
24  
24  
24  
48  
48  
48  
48  
(V)  
3.4  
5.1  
12.1  
15.1  
3.4  
5.1  
12.1  
15.1  
(A)  
(A)  
4.5  
3.0  
1.2  
1.1  
4.1  
2.8  
1.2  
1.0  
(%)  
79  
83  
86  
86  
80  
83  
86  
87  
(µF)  
470  
470  
100  
47  
470  
470  
56  
NPH10S2403i  
NPH10S2405i  
NPH10S2412i  
NPH10S2415i  
NPH10S4803i  
NPH10S4805i  
NPH10S4812i  
NPH10S4815i  
2.94  
1.96  
0.83  
0.67  
2.94  
1.96  
0.83  
0.67  
22  
FEATURES  
INPUT CHARACTERISTICS  
Parameter  
Conditions  
MIN  
18  
36  
NOM  
MAX  
36  
75  
Units  
High Efficiency to 86%  
Power Density up to 1.5kW/L  
Continuous operation, 24V input types  
Continuous operation, 48V input types3  
24  
48  
V
V
Voltage Range  
3
(24W/in )  
1.5kV Input to Output Isolation  
Industry Standard Pinout  
Surge Rating to 12W  
Non Latching Current Limit  
Fixed Frequency  
OUTPUT CHARACTERISTICS  
Parameter  
Conditions  
MIN  
TYP  
MAX  
Units  
Voltage Set  
Point Error  
50% load after 30 mins at nominal  
0.5  
%
supply voltage  
Case temperature –40°C to 110°C  
Load 0% - 100%  
Overall  
1
2.5  
%
Voltage Error  
Input specified range  
Versatile Control Options  
Temperature Coefficient  
of Output Voltage  
(slope)  
Over any 10°C span within the  
specified temperature range  
50  
250 ppm°C  
Continuous Rating to 10W at 72°C  
Without Heatsink  
Deviation of  
Specified over temperature MIN-MAX  
Operating voltage range, 50% load  
0% - 100% rated load  
0.5  
1
%
Output Voltage  
Operation to Zero Load  
Line Regulation  
Load Regulation  
Ripple  
0.05  
0.1  
0.5  
%
%
mV  
Protected Against Load Faults  
Internal Over Temperature Protection  
Uses No Electrolytic Capacitors  
UL 94V-0 Package Materials  
4
rms  
70  
CONTROL CHARACTERISTICS  
Parameter  
Conditions  
MIN  
TYP  
MAX  
Units  
Voltage Trimming  
At rated load,  
10  
%
DESCRIPTION  
Range  
Trim control at either output  
5
Remote Switch Input  
(voltage relative  
Not operating  
-15  
9
0
1.5  
11  
The NPH10S series of DC-DC Converters  
combines ease of application with versatility.  
The pin pattern is based on the popular  
industry standard, but two additional pins  
may optionally be fitted to provide a variety  
of features not commonly found on units of  
this type. High efficiency enables full rating  
to be achieved in a small package without  
heatsinking. Thermally protected against  
sustained overload. The copper case  
achieves efficient heat transfer and screening.  
The product range has been recognised by  
Underwriters Laboratory (UL) to UL 1950 for  
operational insulation, file number E179522  
applies.  
V
to input negative)  
Operating, open circuit voltage  
10  
Time from application of valid input  
Start Delay  
25  
mS  
voltage to output being in specification  
5
Synchronisation  
Specified drive signal  
320  
330  
440  
395  
kHz  
kHz  
Switching Frequency  
350  
ABSOLUTE MAXIMUM RATINGS  
6
6
Input voltage, 24V input types  
Input voltage, 48V input types  
Output Voltage  
Output trim control  
Synchronisation/shutdown control  
–0.5V to 40V  
–0.5V to 80V  
–0.3V to controlled output voltage (operating or non-operating)  
–1V to +30V  
15V relative to input return  
ISOLATION CHARACTERISTICS  
Parameter  
Conditions  
MIN  
1500  
1
TYP  
MAX Units  
VDC  
Isolation Voltage  
Resistance  
Flash tested for 1 second  
Viso=500VDC  
G  
3.3V and 5V output  
12V and 15V output  
50  
90  
Capacitance  
pF  
1 If optional pins ADJ and SS are required (as indicated in the pin connections diagram) prefix the ending “i” with  
an E when ordering, e.g. NPH10S4803Ei.  
2 Current is quoted when output is 95% of regulated voltage.  
3 For applications requiring UL1950 recognition, input voltage must not exceed 60VDC.  
4 A minimum load of 10% of rating is recommended for typical applications ; see application notes.  
5 Optional - Where fitted.  
6 Absolute maximum value for 30 seconds. Prolonged operation may damage the product.  
www.cdpoweronline.com  
All specifications typical at T =25°C, nominal input voltage and rated output current unless otherwise specified.  
A

与NPH10S4803EI相关器件

型号 品牌 获取价格 描述 数据表
NPH10S4803EiC MURATA

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4803I CANDD

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4803iC MURATA

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4805EI CANDD

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4805EiC MURATA

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4805I CANDD

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4805iC MURATA

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4812EI CANDD

获取价格

Isolated 10W Single Output DC/DC Converters
NPH10S4812EIC MURATA

获取价格

民用设备,工业设备
NPH10S4812I CANDD

获取价格

Isolated 10W Single Output DC/DC Converters