Ordering information
Ultra high-attenuation type of common mode noise from 10kHz to 10MHz (2-stage filter)
NBH -10 -432 -O
NBH series
1
2
3
4
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
R
table1.1 Line to ground capacitor code
Line to ground
capacitor
(nominal value)
Leakage Current
(Input 125/250V 60Hz)
Test voltage
(Terminal- Mounting Plate)
Code
CY1
CY2
000
101
221
331
471
681
102
202
322
432
5
A/ 10 A max
12.5 A/ 25 A max
25 A/ 50 A max
37.5 A/ 75 A max
50 A/100 A max
Not Provided Not Provided
100pF Not Provided
220pF Not Provided
330pF Not Provided
470pF Not Provided
680pF Not Provided
1000pF Not Provided
1000pF 1000pF
2200pF 1000pF
3300pF 1000pF
4,000VAC
2,500VAC
75.5 A/150 A max
0.13mA/0.25mA max
0.25mA/0.5 mA max
0.38mA/0.75mA max
0.5 mA/1.0 mA max
DIN rail installation type is option
The terminal cover is retracted inside the unit
When the line to ground capacitor code is different, the attenuation
characteristic is different.
*
4Options
D:DIN rail installation type
The dimensions change when the option is set.
Refer to External view.
*
Features of NBH series
Ultra high-attenuation type of common mode noise from 10kHz to 10MHz (2-stage filter)
-Single Phase 250 VAC
-Push down type terminal block
-Withstand voltage 4,000 VAC
(Line to ground capacitor code -000 to -471)
Specifications
No.
Items
NBH-06-432
NBH-10-432
NBH-16-432
NBH-20-432
NBH-30-432
1
Rated Voltage[V]
AC 1f250 / DC250
2
Rated Current[A]
6
10
16
20
30
1
3
Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
*
4
Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MWmin at room temperature and humidity
5
Leakage current 125/250V 60Hz
Voltage drop
0.5mA/1.0mA max
6
1.0V max
7
Safety agency approval temperatures
Operating temperature
Operating humidity
-25 to +85C(Refer to Derating Curve A)
-40 to +85C(Refer to Derating Curve A)
20 to 95%RH (Non condensing)
-25 to +85C(Refer to Derating Curve B)
-40 to +85C(Refer to Derating Curve B)
8
9
10
11
12
13
14
Storage temperature/humidity
Vibration
-40 to +85C/20 to 95%RH (Non condensing)
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis
2
Impact
196.1m/s (20G), 11ms Once each X, Y and Z axis
Safety agency approvals
Case size (without projection) /Weight
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
53X43X104 mm [2.09X1.69X4.09 inches] (WXHXD) /320g max (Option : -D refer to external view)
1 When the line to ground capacitor code is different, the test voltage characteristic is different. (See table 1.1)
*
Circuit Diagram
Derating Curve
Derating Curve (A) 6,10A
100
80
60
40
20
0
Case
3
1
CY1
CY1
CY2
CY2
-40
-30
-20
40
50
60
70
80 85 90
LOAD
LINE
Ambient Temperature [C]
Derating Curve (B) 16 to 30A
2
4
100
80
60
40
20
0
CY1,CY2 : Line to ground capacitor
: Mounting Plate
-40
-30
-20
40 45 50
60
70
80 85 90
Ambient Temperature [C]
NB-1