MPU150/MDU150 Series Data Sheet
Features
•
RoHS lead free solder and lead solder exempted products
are available
•
•
•
Power Factor Correction (PFC) meets EN61000-3-2
Low-profile height fits 1U constraints
Dual main outputs provide 3.3V and 5V for mixed mode
applications
•
•
•
•
•
•
Single wire current sense on outputs V1 and V2
Remote sense on outputs V1 and V2
Overtemperature, overload, and overvoltage protection
Available with metric or SAE mountings
Greater than 340,000 Hours MTBF
MDU150 models have 48VDC input
Description
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U
height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform to support
mixed-mode, high-speed digital circuitry. Power-One’s unique dual converter architecture combines high reliability with
exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable
losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit.
Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch.
The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.
AC Input, Single Output Model Selection - 180W WITH 300 LFM FORCED-AIR COOLING
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
MPU150-S259
MPU150-S262
MPU150-S261
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
15A (Note 3)
7.5A (Note 3)
3.75A (Note 3)
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
Model numbers highlighted in yellow or shaded are not recommended for new designs. See MPU200 for new designs.
AC Input, Multiple Output Model Selection - 150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+3.3V
+5V
+12V
+5V
+12V
+24V
+5V
+12V
12V
3.15V to 3.80V
5.0V to 5.5V
Fixed
5.0V to 5.5V
10.8V to 13.2V
Fixed
35A
20A
2A
17.5A
4A
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.8%
0.6%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
1.5%
3%
3%
1%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1%
1.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
23.52V to 24.48V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
MPU150-3300
MPU150-3524
MPU150-4000
2A
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.80V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A (Note 4)
8A
3A
2A
5V
+2.5V
+3.3V
12V
5V
+3.3V
+5V
12V
12V
+5V
+3.3V
12V
30A (Note 4)
15A (Note 4)
4A (Note 5)
2A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
MPU150-4230
MPU150-4350
MPU150-4530
1.5%
7%
7%
12V
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under
ALL load conditions. It is recommended that the airflow be applied from the input side of the
power supply blowing towards the output.
4) Total current between V1 and V2 is 30A, maximum rating.
5) Total current between V3 and V4 is 5A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Total power of 180 Watts.
MCD10009 Rev. 1.0, 15-Oct-07
Page 1 of 6
www.power-one.com