MLX92242
2-Wire EOL programmable Hall Effect Latch/Switch
7.
Glossary of Terms
Tesla Units for the magnetic flux density, 1 mT = 10 Gauss
TC
NC
Temperature Coefficient in ppm/°C
Not Connected
ADC
PTC
POR
INL
DNL
PWM
Analog-to-Digital Converter
Programming Through Connector
Power on Reset
Integral Non Linearity
Differential Non Linearity
Pulse Width Modulation
8.
Absolute Maximum Ratings
Parameter
Symbol
Value
Units
(1, 2)
Supply Voltage
VDD
VDD
IDD
+28V
+32V
+20
V
V
Supply Voltage (Load Dump) (1, 4)
Supply Current (1,2 3)
mA
Supply Current (1, 3, 4)
IDD
+50
mA
V
Reverse Supply Voltage (1, 2)
Reverse Supply Voltage (1, 4)
Reverse Supply Current (1, 2, 5)
Reverse Supply Current (1, 4,5)
Maximum Junction Temperature (6)
ESD Sensitivity – HBM (7)
ESD Sensitivity – MM (8)
VDDREV
VDDREV
IDDREV
IDDREV
TJ
-24
-30
V
-20
mA
mA
C
kV
V
-50
+165
8
-
-
400
ESD Sensitivity – CDM (9)
-
1000
Unlimited
V
Magnetic Flux Density
B
mT
Table 1: Absolute maximum ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute
maximum rated conditions for extended periods may affect device reliability.
1 The maximum junction temperature should not be exceeded
2 For maximum 1 hour
3 Including current through protection device
4 For maximum 500ms
5 Through protection device
6 For 1000 hours.
7 Human Model according AEC-Q100-002 standard
8 Machine Model according AEC-Q100-003 standard
9 Charged Device Model according AEC-Q100-011 standard
3901092242
Rev 2
Page 4 of 13
Data Sheet
May/14