MLX90609
Angular Rate Sensor (Standard version)
1. Maximum Ratings
MLX90609 operates without failure, for 6500 hours with a certain temperature profile in the
40°C to +85ºC range.
-
The MLX90609 meets the following maximum ratings over the entire operating temperature range
and supply voltage range unless otherwise indicated. The current polarity is positive if the current
flows into a terminal. All voltages are referenced to VSS.
Parameter.
SupplyꢀVoltage,ꢀVDDꢀ
Min
Max
Units
Comments
Noꢀlatchꢁupꢀorꢀdamage.ꢀ
Riseꢀtimeꢀ(10ꢀtoꢀ90%):ꢀ
trꢀ≥ꢀ0.5ꢂs.ꢀ
ꢁ0.5ꢀ
7ꢀ
Vꢀ
SupplyꢀVoltage,ꢀVDDꢀ
4.75ꢀ
5.25ꢀ
25ꢀ
Vꢀ
Operatingꢀwithinꢀspecificationsꢀ
VDDꢀ=ꢀ0ꢀtoꢀ7Vꢀ
guaranteedꢀbyꢀcharacterizationꢀ
Outputꢀpinsꢀ(OUTAR,ꢀOUTTEMP,ꢀallꢀdigitalꢀIO’s)ꢀ
currentꢀlimit,ꢀshortedꢀtoꢀVDDꢀorꢀVSSꢀpinꢀ
ꢀ
mAꢀ
OperatingꢀTemperatureꢀRange,ꢀTAMBIENT
ꢀ
ꢁ40ꢀ
ꢁ40ꢀ
ꢁ55ꢀ
85ꢀ
ꢀ
°Cꢀ
°Cꢀ
°Cꢀ
OperatingꢀTemperatureꢀRange,ꢀTJUNCTION
StorageꢀTemperatureꢀRangeꢀ
ꢀ
110ꢀ
125ꢀ
100ꢀ
Outputꢀnotꢀshortedꢀ
ꢀ
ꢀ
PackageꢀThermalꢀResistanceꢀ
ꢀ
ꢀ
°C/Wꢀ
mAꢀ
gꢀ
CDFꢀꢁꢀAECꢀꢁꢀQ100ꢁ004;ꢀ
VDD=ꢀ5.75Vꢀ
Latchꢁupꢀwithstandꢀ
ꢁ150ꢀ
150ꢀ
Accelerationꢀshockꢀsurvivalꢀ
±1500ꢀ
Shockꢀ0.5ms,ꢀ3ꢀaxisꢀ
Table 1. Absolute maximum ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
390109060901
Rev 008
Page 3 of 22
Data Sheet
February/08