MLX90215
Position Programmable Linear Hall Effect Sensor
6. Electrical specifications
DC Operating Parameters TA = -40oC to 150oC, VDD = 5.0V (Unless otherwise specified)
Parameter
Symbol Test Conditions
Min Typ Max Units
Supply Voltage
Supply Current
Output Current
VDD
IOUT
Operating
4.5
2.5
-2
5.0
4.0
-
5.5
6.5
2
V
B = 0, VDD = 5V, IOUT = 0
VDD = 5V ± 10%
mA
mA
V
(1)
10 – Bit Programmable, B =
0
(2)
Quiescent Output Voltage
VOQ
VOH
VOL
0.5
4.5
-
4.5
(1)
Output Voltage
VDD = 5V, IOUT = -2mA
VDD = 5V, IOUT = 2mA
RoughGain @ Max and Min
RoughGain @ Min
4.65
V
(1)
Output Voltage
0.35 0.50
V
Sampling Rate
fSAMP
BW
4
-
-
-
-
40
kHz
(3)
Bandwidth
1.300 kHz
(3)
Bandwidth
BW
RoughGain @ Max
RoughGain @ Min
RoughGain @ Max
0.130
25
kHz
µs
(6)
Step Response Time
TRMIN
TRMIN
ΔVOQ
(6)
Step Response Time
250
µs
B – 0, TA – 25°C, ½ VDD – 1
B = 0, TA = 25°C, ½ VDD = 0
B = 0, TA = -40°C to 150°C
-1.5
-6
1.5
6
mV
mV
Offset Voltage Adjustment Resolution
Offset Voltage Drift over Temperature
-
-
ΔVOQ/ΔT S < 100mV/mT & VOQ
>
-20
-40
20
40
mV
mV
0.75V
B = 0, TA = -40°C to 150°C
Offset Voltage Drift over Temperature
ΔVOQ/ΔT S > 100mV/mT & VOQ
<
-
(2)
0.75V
(7)
Range of Sensitivity
S
13 – Bit Programmable
5
8
-
140
60
mV/mT
(4)
Peak to Peak Noise
25
6
-
mV
Ω
Output Resistance
ROUT
(5)
Sensitivity Drift
TA = 25°C
-1
1
%
Notes:
(1) If output current and voltage specifications are exceeded, linearity will be degraded.
REVISION 009 - AUGUST 21, 2017
3901090215
Page 4 of 15