MKW2000 SERIES
DC/DC CONVERTER 12W
Total Power International, Inc.
Output Specifications
Parameter
Conditions
Min.
---
Typ.
---
Max.
±1.0
±2.0
±0.5
±1.0
±0.5
75
Unit
%Vom.
%
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
At 50% Load and Nominal Vin
Dual Output, Balanced Loads
Vin=Min. to Max.
---
±0.5
±0.1
±0.8
±0.2
50
---
%
Io=10% to 100% (3.3Vo)
Io=10% to 100%
---
%
Load Regulation
---
%
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
---
mV P-P
μsec
%
---
150
250
25% Load Step Change
Foldback
---
±1.5
±0.01
TBD
±2.5
±0.02
---
---
%/℃
%
120
Short Circuit Protection
Continuous
General Specifications
Parameter
Conditions
60 Seconds
500 VDC
Min.
1500
1000
---
Typ.
---
Max.
---
Unit
VDC
MΩ
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
---
---
100KHz, 1V
500
350
---
650
400
---
pF
300
KHz
Hours
MIL-HDBK-217F@25℃, Ground Benign
700,000
Safety Approvals
UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1
Input Fuse
24V Input Models
1500mA Slow-Blow Type
48V Input Models
750mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Conditions
Min.
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
Natural Convection
-40
---
Storage Temperature Range
-50
Humidity (non condensing)
---
Cooling
Free-Air convection
---
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Power Derating Curve
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com