350 Watts
xppower.com
MFA350 Series
•
•
•
•
•
•
•
Screw Terminals Available
U-Channel, Cover Fan & Hotswap Formats
High Power Density up to 11.1 W/in3
-10 °C to +70 °C Operation
Power Fail, DC OK & Active Current Share
5 V Standby & 12 V Fan Supply Outputs
48 VDC Input Versions Available (DFA350)
Specification
Input
General
Input Voltage
• 85-264 VAC
(derate output power 10% below 90 VAC)
Efficiency
Isolation
• Typically 86%
• 3000 VAC Input to Output
1500 VAC Input to Ground
100 VDC Output to Ground
Input Frequency
Input Current
• 47-63 Hz
• Typically 3.6 A at 115 VAC &
1.8 A at 230 VAC
Switching Frequency
• Typically PFC 62 kHz,
main converter 157 kHz
• 11.1 W/In3
Inrush Current
Power Factor
• <60 A max at 230 VAC cold start
Power Density
Signals
• >0.9 harmonics compliant with
EN61000-3-2 Class A
• Power Fail - open collector, transistor off
for AC good, ≥5 ms warning of loss of
output. DC OK - open collector, transistor
off for DC good
Earth Leakage Current • Typically 1 mA at 230 VAC/50 Hz,
0.5 mA at 115 VAC/60 Hz
Input Protection
• T6.3 A/250 V internal in line fuse
MTBF
• Typically 460 kHrs to MIL-HDBK-217F,
notice 2, +25 °C GB
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Hold Up Time
Drift
• See tables
Environmental
•
10%
Operating Temperature • Forced cooled: -10 °C to +70 °C, derate
• V1 1%, V2 5%, V3 3%
• No minimum load required
• 2 s maximum, typically 1 s
• 16 ms minimum at 90 VAC full load
linearly from +50 °C at 2.5%/°C to +70 °C
Cooling
• >13 CFM forced airflow required for U
Channel Versions, ‘-H’, ‘-TF’ & ‘-EF’
versions have integral fan
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 5-95% RH
• -20 °C to +85 °C
• 3000 m
•
0.2% after 20 min warm-up
Line Regulation
Load Regulation
• V1 0.5%, V2 3.0%, V3 0.5%
• V1 1.0%, V2 5.0%, V3 1.0%,
0-100% load V1 & V3, 10-100% load V2
• 3 x 30 g/11 ms shocks in both +ve & -ve
directions along the 3 orthogonal axes,
total 18 shocks.
Over/Undershoot
• <1% maximum
Transient Response
• <4% max deviation,with 50-75-50% load
step. Recovery to within 1% <500 µs
Vibration
• Single axis 10-500 Hz at 2 g x 10 sweeps
Ripple & Noise
• V1 & V3: 1%, V2: 2% pk-pk, 20 MHz BW
EMC & Safety
Overvoltage Protection • 115-140% Vnom (output V1 only)
Emissions
• EN55022, Class B conducted
EN55022, Class A radiated
Overtemperature
Protection
• Thermal sensor under PCB shuts unit
down typically >+75 °C
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
• EN61000-3-2, Class A
Overload Protection
• 110-140%, I nom V1
• EN61000-3-3
Short Circuit Protection • Continuous
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V rms Perf Criteria A
• EN61000-4-11 Perf Criteria A, B, B
Temperature
Coefficient
• 0.05%/ºC
Surge
Remote Sense
Remote On/Off
• Compensates for 0.5 V total voltage drop
Conducted Immunity
Dips & Interruptions
Safety Approvals
• Short circuit or TTL Low turns PSU off,
can also be configured as enable
• CB Report, IEC60950-1:2001,
CSA22.2 No. 60950-1-05,
UL60950-1 (2003),
Current Share
• Up to 3 supplies can be connected in
parallel, derate total output current to 90%
TUV EN60950-1/A11:2004,
CCC pending contact sales