Data Sheet
MAX86176/MAX30005
Ultra-Low-Power, Optical PPG and Single-Lead ECG AFE
General Description
Benefits and Features
PPG (MAX86176)
● Complete Dual-Channel Optical-Data Acquisition System
● Ultra-Low-Power Operation for Wearable Devices
• Optical Readout Channel < 11μA (typ) at 25fps
• 14.6μs to 117.1μs ADC Integration Time
• Low Shutdown Current < 1μA (typ)
The MAX86176 is a complete photoplethysmogram (PPG)
and electrocardiogram (ECG) analog front-end (AFE) solution
for wearable applications. The MAX30005 is a complete AFE
solution for ECG only. Both AFEs offer high performance for
fitness and clinical applications with ultra-low power for long
battery life.
● Signal to Noise Ratio (SNR) up to 110dB with Average
(Avg) Mode and Off-Chip Filtering
● Supports Frame Rates from 1fps to 2kfps
● High-Resolution 20-bit Charge-Integrating ADCs
Both MAX86176 and MAX30005 feature an ECG channel,
EMI filtering, internal-lead biasing, AC and DC lead-off detec-
tion, right-leg drive, ultra-low power DC lead-on detection
during standby mode, and extensive calibration voltages for
built in self-test. In addition, the MAX86176 has a PPG data
acquisition system supporting up to 6 LEDs and 4 photodiode
inputs, which is fully synchronized with the ECG signal path.
The MAX86176/MAX30005 can operate with either internal
or external clock. The MAX86176/MAX30005 are designed
to meet IEC 60601-2-47 Ambulatory ECG Systems monitor-
ing compliance for even the most challenging dry electrode
applications.
● Low Dark-Current Noise of < 50pA
RMS
● Excellent Ambient Range and Rejection Capability
• > 100μA Ambient Photodiode Current
• > 90dB Ambient Rejection at 120Hz (Avg > 2)
ECG (MAX86176/MAX30005)
● Clinical-Grade ECG AFE with High-Resolution ADC
• 15.6 ENOB with 0.6μV
Noise over 0.05Hz to 40Hz
RMS
● Very Low Input-Bias Current (-40°C to +85°C)
• 233fA Input-Current Noise (0.05Hz to 40Hz,
The MAX86176/MAX30005 are available in a 6x6 36-bump
wafer-level packages (WLP), operating over the -40ºC to
+85ºC temperature range.
RMS
T = +25°C)
A
● Fully Differential Input Structure with CMRR > 110dB at
Power-Line Frequencies
● High-Input Impedance > 1GΩ for Extremely Low
Common to Differential-Mode Conversion
● High DC-Offset Range of ±1300mV (typ 1.8V) Allows a
Wide Variety of Electrodes to be Used
Applications
PPG (MAX86176)
● Wearable Devices for Fitness, Wellness and Medical
Applications with Clinical Accuracy
● Suitable for Wrist, Finger, Ear and Other Locations
● Optimized Performance to Detect Heart Rate, Oxygen
● High AC-Dynamic Range of > 90mV
Helps Prevent
P-P
Saturation in the Presence of Motion
● ECG Biopotential Channel Can Be Used for Some EEG
Applications
Saturation (SpO ), Muscle and Tissue Oxygen Satura-
2
tion(SmO and StO ), and Body Hydration
2
2
ECG (MAX86176/MAX30005)
● Single-Lead Event Monitors for Atrial Fibrillation (A-Fib)
and other Arrhythmia Detection
• Higher-Gain Ranges Available (480V/V, 960V/V)
• Low Input-Referred Voltage and Current Noise Enables
Use of Small-Area Dry Electrodes
● Single-Lead Wireless Patches for At-Home/In-Hospital
Monitoring
● Chest-Band Heart-Rate Monitors for Fitness Applications
● Biometric Authentication and ECG-on-Demand Applications
SYSTEM
● Shutdown Current of 0.5μA (typ)
● 256-Word FIFO for ECG and PPG
● True Synchronous ECG and PPG Data from Dedicated
Signal Paths
PPG-ECG SYNC (MAX86176)
● Fully Synchronized PPG and ECG Signal Path for PTT
Measurements
● Two Fully Configurable Interrupts
● High-Speed SPI Interface or I C Interface
2
● Small 2.728mm x 2.708mm WLP Package
Visit Web Support to complete the nondisclosure agreement (NDA) required to receive additional product information.
Rev. 3
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices
DOCUMENT FEEDBACK
for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change
without notice. No license is granted by implicationor otherwise under any patent or patent rights of Analog Devices. Trademarks andregistered
trademarks are the property of their respective owners.
TECHNICAL SUPPORT