LZ23H3V1
RECOMMENDED OPERATING CONDITIONS
PARAMETER
Ambient operating temperature
Output transistor drain voltage
Overflow drain clock p-p level
Ground
SYMBOL
MIN.
TYP. MAX. UNIT NOTE
TOPR
VOD
VØOFD
25.0
14.55 15.0 15.45
24.5
˚C
V
26.5
V
V
V
1
2
GND
0.0
P-well voltage
VPW
–10.0
–9.5
VØVL
–8.5
VØV1AL, VØV1BL, VØV2L
VØV3AL, VØV3BL, VØV4L
VØV1AI, VØV1BI, VØV2I
VØV3AI, VØV3BI, VØV4I
VØV1AH, VØV1BH
VØV3AH, VØV3BH
VØH1L, VØH2L
VØH1H, VØH2H
VØRS
LOW level
–9.0
0.0
V
V
V
Vertical shift
register clock
INTERMEDIATE level
HIGH level
14.55 15.0 15.45
Horizontal shift
register clock
LOW level
HIGH level
Reset gate clock p-p level
–0.05
4.5
4.5
0.0
5.0
0.05
5.5
V
V
5.0
5.5
V
1
3
4
3
4
3
4
fØV1A, fØV1B, fØV2
fØV3A, fØV3B, fØV4
10.88
13.47
14.32
18.00
14.32
18.00
kHz
kHz
MHz
MHz
MHz
MHz
Vertical shift register clock frequency
Horizontal shift register clock frequency
fØH1, fØH2
fØRS
Reset gate clock frequency
NOTES :
1. Use the circuit parameter indicated in "SYSTEM CONFIGURATION EXAMPLE", and do not connect to DC voltage directly.
2. VPW is set below VØVL that is low level of vertical shift register clock, or is used with the same power supply that is connected
to VL of V driver IC.
3. Operation frequency is 14.32 MHz.
4. Operation frequency is 18.00 MHz.
* To apply power, first connect GND and then turn on VOD. After turning on VOD, turn on PW first and then turn on other powers
and pulses. Do not connect the device to or disconnect it from the plug socket while power is being applied.