Spec No.: JELF243A_9135G-01
P1/8
CHIP COILS (CHIP INDUCTORS) LQH32PH□□□□NC□
Murata Standard Reference Specification [AEC-Q200]
1. Scope
This reference specification applies to chip coils (chip inductors) LQH32PH_NC series for automotive electronics based on
AEC-Q200.
2. Part Numbering
(Ex.)
LQ
H
32
P
H
1R0
N
N
C
L
Product ID Structure Dimension Application and Category Inductance Tolerance Dimension Other
Packaging
L: ø180 taping
*B: bulk
(L × W)
characteristic
(T)
*B: Bulk packing is also available.
3. Part Number and Rating
Operating temperature range
(ambient temperature not including self-temperature rise)
(product temperature including self-temperature rise)
-40°C to +105°C
-40°C to +125°C
-40°C to +125°C
Storage temperature range
Rated current
(mA)*3
Inductance
Self-resonant
DC resistance
Based on temperature
rise*2
Customer
Part number
Murata
Part number
ESD
5 A: 8 kV
frequency
Nominal
value
(μH)
Based on
(Ω)
Tolerance
(%)
(MHz min.)
inductance
Ambient
Ambient
change*1
temperature temperature
85°C
2900
2500
2100
1850
1550
1200
1100
900
105°C
1490
1380
1110
910
LQH32PHR47NNCL
LQH32PH1R0NNCL
LQH32PH1R5NNCL
LQH32PH2R2NNCL
LQH32PH3R3NNCL
LQH32PH4R7NNCL
LQH32PH6R8NNCL
LQH32PH100MNCL
LQH32PH150MNCL
LQH32PH220MNCL
0.47
1.0
1.5
2.2
3.3
4.7
6.8
10
N: ±30 0.024±20%
N: ±30 0.036±20%
N: ±30 0.053±20%
N: ±30 0.064±20%
N: ±30 0.100±20%
N: ±30 0.155±20%
N: ±30 0.220±20%
M: ±20 0.295±20%
M: ±20 0.475±20%
M: ±20 0.685±20%
100
100
70
70
50
40
40
30
20
20
4400
3000
2600
2000
1900
1600
1300
1000
800
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
800
610
550
450
15
700
330
22
650
550
270
*1 When rated current is applied to the products, inductance will be within ±30% of nominal inductance value.
*2 When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 40°C max
(ambient temperature 85°C max).
When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 20°C max
(ambient temperature 85°C to 105°C).
*3 Keep the temperature (ambient temperature plus self-generation of heat) under 125°C.
4. Testing Conditions
Unless otherwise specified
Temperature: ordinary temperature (15°C to 35°C)
Humidity: ordinary humidity [25% to 85% (RH)]
In case of doubt
Temperature: 20°C±2°C
Humidity: 60% to 70% (RH)
Atmospheric pressure: 86 kPa to 106 kPa
MURATA MFG CO., LTD